Technical article 127670

How to redirect console output during ISL

OpenServer 5.0.7

Written · Last revised

Problem

I need to redirect the output from ISL to a serial console.

Solution

Following a description for OpenServer 5.0.7.

Install "putty" on a Windows system and set session=serial Serial line=COM1 Speed=9600

Then click on Serial and set Serial line to connect to=COM1 Speed=9600 Data bits=8 Stop bits=1 Parity=None Flow control=None

Use a standard serial cable and connect COM1 on your server with COM1 on your Windows system. Make sure COM1 is enabled in the BIOS on both systems (defaults are I/O=3F8 and IRQ=4).

Boot from the OpenServer 5.0.7 boot CD and at the boot promt type

: defbootstr systty=sio <ENTER>

The installation will start as normal but when switching to the "hwconfig"-like screen you will get the output on the "putty" window. You will be asked Enter terminal type code

Enter "ansi". You are now ready to install the system.