Technical article 125238

I get the error: "Unable to initialize device" when using SCO Update...

OpenServer 5.0.7

Written · Last revised

Problem

I am trying to use the new "SCO Update..." of the Software Manager (custom) to apply the latest SCO OpenServer Update Pack to my system. But when I choose from the menu bar:

Software -> SCO Update...
I get the error message:
Unable to initialize device

If I click on "Details..." I see:

Error querying remote devices Error completing mmdevice command Unable to establish data connection Error obtaining connection Connection timed out

Cause

The "SCO Update..." feature of the Software Manager requires the ability to create both outgoing and incoming ftp connections. If your system is behind a firewall that prevents incoming ftp connections then you will get the error message mentioned above.

Solution

This problem has been reported to SCO Engineering and will be fixed in a future release of product.

There are two possible workarounds to the problem:

1) Manually download the SCO OpenServer Update from:

http://www.sco.com/support/update/download/osr507up.html
and install it on your system.

2) Modify your firewall to temporarily allow incoming ftp sessions.

NOTE:     Allowing incoming may pose a security risk to your intranet and
          for this reason we only recommend the 1st workaround.

From the Xinuos technical article database, record 125238. Reproduced with permission. The original is at www.sco.com/ta/125238, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.