Problem

I want to install a HP server (for example DL380G5) using a USB floppy. During initialization I get an error similar to this one:

usb_msto: Inquiry Read failed, Unbinding! usb_msto: Please disconnect and re-attach the device to try again. T.7455-usb_msto0 0300 3.2 <Drvr16>: Initialization failure. Please re-attach the device to retry.

Solution

Different USB floppy models may work in different ways.

The TEAC FD 05-PUW is known to work.

Further make sure that the USB floppy is connected when you power on your system.

To load the BTLD driver from the USB floppy use the following bootstring, for example:

defbootstr link=hpsas hd=Sdsk Sdsk=hpsas(0,0,0,0)

You may be asked after creation of the filesystem which floppy you are using (floppy0 or floppy1). Choose floppy1.