SCO OpenServer Release 5.0.7 Maintenance Pack 4 Release and Installation Notes
Solution
What follows are the Release and Installation notes for SCO OpenServer Release 5.0.7 Maintenance Pack 4. For Release and Installation Notes in ASCII, HTML and PDF format please see:
http://www.sco.com/support/update/download/release.php?rid=116SCO OpenServer Release 5.0.7 Maintenance Pack 4 Release and Installation Notes
The SCO OpenServer(TM) Maintenance Pack 4 contains important fixes for your SCO OpenServer Release 5.0.7 system and should be applied at your next maintenance period.
_________________________________________________________________________
NOTE Maintenance Pack 4 is the third in the series of Maintenance
Packs provided for SCO OpenServer Release 5.0.7. Because the
previous Maintenance Pack was coordinated with the release of
Update Pack 3, there was no Maintenance Pack 2.
_________________________________________________________________________These Release and Installation Notes contain critical information that
you need to know before and after installing SCO OpenServer Release 5.0.7
Maintenance Pack 4. Please familiarize yourself with the information
that is relevant to your system, then install the Maintenance Pack
according to the instructions in this document._________________________________________________________________________
NOTE Unless otherwise noted, this document supplements the SCO
OpenServer Release 5.0.7 Late News, which are still relevant. As
information becomes available after the publication of these
Release and Installation Notes, it is added to the SCO OpenServer
Release 5.0.7 Late News document, available from the SCO web site
at:http://www.sco.com/support/docs/openserver_________________________________________________________________________These Release and Installation Notes cover the following topics:
+ About Maintenance Packs and Update Packs+ Before installing the Maintenance Pack+ Installing the Maintenance Pack+ Highlights of the Maintenance Pack+ Maintenance Pack notes and limitationsAbout Maintenance Packs and Update PacksHistorically, there were two support ``tracks'' that were available to
SCO OpenServer Release 5.0.7 customers:Maintenance Packs
A Maintenance Pack (MP) is a collection of security updates and
fixes for reported problems. Maintenance Packs are made available
periodically and can be downloaded and installed free-of-charge.
Maintenance Packs are cumulative, so only the latest one needs to be
installed.Update Packs
An Update Pack (UP) is a collection of some of the new features and
product enhancements that will be included in the next SCO
OpenServer release. Available only for registered subscribers to
the SCO Update Service, Update Packs provide a simplified and
streamlined process for deploying new technology and keeping systems
updated.With the release of Maintenance Pack 4, the SCO OpenServer Release 5.0.7 Update Pack track is discontinued and new licenses are no longer available. All of the functionality from Update Pack 3 is now available in Maintenance Pack 4.
Obtaining Maintenance PacksSCO OpenServer Maintenance Pack 4 is available for download from the SCO OpenServer Release 5.0.7 Supplements web page:
http://www.sco.com/support/update/download/osr507list.htmlAdditionally, SCO OpenServer Maintenance Pack 4 is included on the SCO
OpenServer Release 5.0.7 Supplement CD Version 4. The SCO OpenServer
Release 5.0.7 Supplement CD also provides other new and updated
components, including Java, Samba, Squid, and updated graphics, NIC, and
HBA drivers. Your SCO OpenServer media kit may contain Version 4 of the
Supplement CD; if not, you can download the ISO image for this CD from
the SCO OpenServer Release 5.0.7 Supplements web page
(http://www.sco.com/support/update/download/osr507list.html).Before installing the Maintenance Pack from the Supplement CD, check the SCO OpenServer Release 5.0.7 Supplements web page to verify that the Supplement CD contains the most current Maintenance Pack available.
Before installing the Maintenance PackBefore installing SCO OpenServer Release 5.0.7 Maintenance Pack 4, note the following:
+ Back up the data on your system and verify the integrity of the
backup.+ To prevent the possibility of introducing software conflicts on your
system, you are strongly encouraged to install Maintenance Pack 4 in
its entirety. At a minimum, you must install the following components
from Maintenance Pack 4:- the RS507C Release Supplement -- a critical requirement for the
other components in the Maintenance Pack to function correctly.- the Perl package and the Supplemental Graphics, Web, and X11
Libraries (GWXLIBS) package -- several other packages, such as
Apache and OpenSSH, depend on these libraries and will fail with
dynamic linker errors if they are not present.- any component of the Maintenance Pack that updates existing
software.+ Maintenance Pack 4 can only be installed on SCO OpenServer Release
5.0.7 systems.+ Maintenance Pack 4 supersedes the following Supplements:- SLS OSS631 -- Supplemental Graphics, Web, and X11 Libraries- SLS OSS646 -- Execution Environment Supplement- SLS OSS656 -- Licensing Update- SLS OSS662 -- MP1 Supplement- SLS OSS669 -- Socket Driver Supplement- SLS OSS671 -- setclk Supplement- Large Filesystem Performance Supplement (lpfs)- wd Driver Supplement_________________________________________________________________________
NOTE Do not install any of these supplements on your system
after you have installed this Maintenance Pack.
_________________________________________________________________________+ Before installing the Maintenance Pack, you should remove
OSS646A/OSS646B and OSS656A/OSS656B.It is not necessary to remove any of the supplements listed above before installing MP4.
+ When you remove the recommended supplements, you do not need to reboot
the system after the kernel is re-linked. The Maintenance Pack
installation also re-links the kernel -- you can reboot at that point.+ Do not install any of the other products provided on the SCO
OpenServer Release 5.0.7 Supplement CD Version 4 until you have first
installed Maintenance Pack 4. See /info/readme.htm on the Supplement
CD for information on issues that affect the order in which certain
products on the CD should be installed.Maintenance Pack Installation_________________________________________________________________________
NOTE Be sure to read ``Before installing the Maintenance Pack''
prior to starting this procedure.
_________________________________________________________________________You can acquire and install SCO OpenServer Release 5.0.7 Maintenance Pack 4:
+ directly over the Internet using the SCO Update function in the
Software Manager.+ by downloading the MP media images from either the SCO web site or FTP
site.+ from the SCO OpenServer Release 5.0.7 Supplement CD Version 4.If there are multiple systems on your TCP/IP network that require
Maintenance Pack 4, you can load and install the MP on a software server
and use it as a centralized distribution point. See ``Installing the
Maintenance Pack across the network'' for more information.Installing the Maintenance Pack using SCO UpdateSCO Update allows you to install Maintenance Packs directly over the
Internet. This approach saves you the time -- and extra hard disk space
-- of first downloading installable image files from the SCO web or FTP
sites._________________________________________________________________________
NOTE Maintenance Pack 1 added support for SCO Update to the
Software Manager. If a previous Maintenance Pack was never
installed on your system, SCO Update will not be available from
within the Software Manager until after you install MP4.
__________________________________________________________________________________________________________________________________________________
NOTE You will not be able to use the SCO Update feature if you are
behind a firewall that prevents incoming FTP connections (i.e., the
use of passive FTP is required). If you try to connect to the SCO
Update server in this situation, the Software Manager displays the
following timeout message after a few minutes:Unable to initialize device A fix for this problem will be made available in a future
supplement or release.
_________________________________________________________________________To use SCO Update:1. Log in as root.2. Start the Software Manager by double-clicking on its icon on the
desktop, or by entering the following at the command-line prompt:scoadmin software3. From the Software menu, select SCO Update. The system connects to
the SCO Update server.The Install Selection window displays all of the SCO OpenServer Release 5.0.7 maintenance packs, drivers, and so forth that are currently available.
4. Highlight Maintenance Pack 4 and click on Install.The selected software is automatically downloaded and installed on your system.
________________________________________________________________________
WARNING The Software Manager displays one or more warnings if
the Maintenance Pack contains fixes for software features that
are not currently installed on your system. If you do not plan
to install the affected package (for example, SMP), you can
ignore such messages and click on Continue. However, if you do
plan to install this package later, you should stop the install
process now by clicking on Cancel, install the package in
question from the installation media, and restart the
Maintenance Pack installation. This ensures the fixes are
applied properly (and avoids potential problems). If any Maintenance Pack fixes were not installed because the
corresponding feature was not present, the Software Manager
shows the Maintenance Pack as only partially installed. This
is normal.
________________________________________________________________________5. When the installation is complete, click on OK.6. Exit the Software Manager by selecting the Host menu, then Exit.7. Reboot the machine. (Because the Software Manager relinks the
kernel, you must reboot before the new kernel takes effect.)We recommend that you use SCO Update periodically to check for new updates, fixes, or drivers for SCO OpenServer Release 5.0.7.
Installing the Maintenance Pack from downloaded media imagesTo install the SCO OpenServer Release 5.0.7 Maintenance Pack 4 from media images that you manually download:
1. Log in as root.2. Download the Maintenance Pack from either the SCO web site or using
FTP:+ to use the web, go to the SCO OpenServer Release 5.0.7 Supplement
web page:http://www.sco.com/support/update/download/osr507list.html+ to use FTP, go to the SCO Support Download Area for SCO OpenServer
Release 5.0.7 Maintenance Pack 4:https://ftp.scoexpert.com/openserver5/507/mp/osr507mp4________________________________________________________________________
NOTE Maintenance Pack 4 consists of a tar archive containing a
number of media image files with names of the form VOL.000.000,
VOL.000.001, and so forth. Because all maintenance packs use
this same filename scheme, you should create a master directory
with a unique subdirectory to store each pack. The master
directory could be /usr/updates, /usr/spool/patches, or
whatever suits your system layout. The master hierarchy should
be writable by root only.
________________________________________________________________________3. Download the osr507mp4_vol.tar file and use this command to extract
the media image files:tar xvf osr507mp4_vol.tar4. Start the Software Manager by double-clicking on its icon on the
desktop, or by entering the following at the command-line prompt:scoadmin software5. From the Software menu, select Install New.6. When prompted for the host (machine), select the current host and
then click on Continue.7. Select Media Images as the Media Device, then click on Continue.
(You may need to scroll down before you see the Media Images option.)8. Enter the absolute pathname for the directory that contains the
Maintenance Pack 4 media images. For example:/usr/spool/patches/osr507mp4Click on OK.9. In the Install Selection window, make sure that the Maintenance Pack
is highlighted, then click on Install.________________________________________________________________________
NOTE Any component of the Maintenance Pack that updates
existing software (such as the RS507C Release Supplement) must
be installed. New features are optional.
________________________________________________________________________10. If you previously installed any of the components that are modified
by the Maintenance Pack, you are notified that these components will
be upgraded. Click on Continue.Additionally, you are warned if certain packages in the Maintenance
Pack will not be installed because the software they modify is not
installed on your system. Click on Continue.________________________________________________________________________
WARNING The Software Manager displays one or more warnings if
the Maintenance Pack contains fixes for software features that
are not currently installed on your system. If you do not plan
to install the affected package (for example, SMP), you can
ignore such messages and click on Continue. However, if you do
plan to install this package later, you should stop the install
process now by clicking on Cancel, install the package in
question from the installation media, and restart the
Maintenance Pack installation. This ensures the fixes are
applied properly (and avoids potential problems). If any Maintenance Pack fixes were not installed because the
corresponding feature was not present, the Software Manager
shows the Maintenance Pack as only partially installed. This
is normal.
________________________________________________________________________11. When the installation is complete, click on OK. The Software Manager
lists Maintenance Pack 4 among the installed software.12. Exit the Software Manager by selecting the Host menu, then Exit.
13. Reboot the machine. (Because the Software Manager relinks the
kernel, you must reboot before the new kernel takes effect.)Installing the Maintenance Pack from CD-ROMThe SCO OpenServer Release 5.0.7 Maintenance Pack 4 is included on the
SCO OpenServer Release 5.0.7 Supplement CD Version 4. Your SCO
OpenServer media kit may contain Version 4 of the Supplement CD; if not,
you can download the ISO image for this CD from the SCO OpenServer
Release 5.0.7 Supplements web page
(http://www.sco.com/support/update/download/osr507list.html).To install the SCO OpenServer Release 5.0.7 Maintenance Pack 4 from the SCO OpenServer Release 5.0.7 Supplement CD Version 4:
1. Log in as root.2. Insert the SCO OpenServer Release 5.0.7 Supplement CD Version 4 into
the drive.3. Start the Software Manager by double-clicking on its icon on the
desktop, or by entering the following at the command-line prompt:scoadmin software4. From the Software menu, select Install New.5. When prompted for the host (machine), select the current host and
then click on Continue.6. Select the appropriate CD-ROM drive as the Media Device, then click
on Continue.7. In the Install Selection window, make sure that the Maintenance Pack
is highlighted, then click on Install.________________________________________________________________________
NOTE Any component of the Maintenance Pack that updates
existing software (such as the RS507C Release Supplement) must
be installed. New features are optional.
________________________________________________________________________8. If you previously installed any of the components that are modified
by the Maintenance Pack, you are notified that these components will
be upgraded. Click on Continue.________________________________________________________________________
WARNING The Software Manager displays one or more warnings if
the Maintenance Pack contains fixes for software features that
are not currently installed on your system. If you do not plan
to install the affected package (for example, SMP), you can
ignore such messages and click on Continue. However, if you do
plan to install this package later, you should stop the install
process now by clicking on Cancel, install the package in
question from the installation media, and restart the
Maintenance Pack installation. This ensures the fixes are
applied properly (and avoids potential problems). If any Maintenance Pack fixes were not installed because the
corresponding feature was not present, the Software Manager
shows the Maintenance Pack as only partially installed. This
is normal.
________________________________________________________________________9. When the installation is complete, click on OK. The Software Manager
lists Maintenance Pack 4 among the installed software.10. Exit the Software Manager by selecting the Host menu, then Exit.
11. Reboot the machine. (Because the Software Manager relinks the
kernel, you must reboot before the new kernel takes effect.)Installing the Maintenance Pack across the networkYou can install SCO OpenServer Release 5.0.7 Maintenance Pack 4 from one
SCO OpenServer Release 5.0.7 system onto another across a TCP/IP network.
To do so, you need a software server, which you can create as described
in ``Installing and managing software over the network'' in the SCO
OpenServer Networking Guide. This server has a user account called
swadmin.Install or load Maintenance Pack 4 on the software server using one of
the installation procedures described in ``Maintenance Pack
Installation''. Also see ``Installing and managing software components''
in the SCO OpenServer Handbook for more information on loading software.To install Maintenance Pack 4 onto a local machine once the Maintenance
Pack is available from the software server, start the Software Manager
and select Install New. In the Begin Installation window, you are
prompted for the source location of the Maintenance Pack. Select From
Another Host. You need to provide the name of the software server, as
well as the password of the swadmin user on the software server.Removing a Maintenance Pack_________________________________________________________________________
WARNING Because of interdependencies between the components that
are included in Maintenance Packs, partial removal of an MP is not
supported.Removing Maintenance Pack 4 de-installs the Apache, Mozilla,
OpenSSH, Perl, and Supplemental Graphics, Web, and X11 Libraries
(GWXLIBS) components. When these components are removed, many
system functions will cease to work, including Squid, Samba, and
the GNU Development Tools (if installed). After removing the Maintenance Pack, it is imperative that you re-
install the previous versions of Apache, Mozilla, OpenSSH, Perl,
and Supplemental Graphics, Web, and GWXLIBS. This section explains
how to do this.
_________________________________________________________________________To remove the Maintenance Pack and reinstall your previous versions of the Apache, Mozilla, OpenSSH, Perl, and GWXLIBS components:
1. Log in as root.2. Start the Software Manager by double-clicking its icon on the
desktop, or by entering the following at the command-line prompt:scoadmin software3. Select the Maintenance Pack in the list of installed software.4. From the Software menu, select Remove Software. In the confirmation
window, verify that you selected the correct software, then click on
Remove.5. A window displays, showing you a list of software that will stop
functioning after the Maintenance Pack is removed. Click on
Continue.6. When the Removal complete window appears, click on OK and exit the
Software Manager by selecting Exit from the Host menu.7. Now re-install Apache, Mozilla, OpenSSH, Perl, and GWXLIBS.It is important that you replace these components with the versions
that you were running prior to installing Maintenance Pack 4. If your
system contains Maintenance Pack 3, use that media. If Maintenance
Pack 4 was the first maintenance pack installed on your system, use
the SCO OpenServer Release 5.0.7 System CD-ROM.8. Restart the Software Manager, as you did in Step 2.9. From the Software menu, select Install New.10. When prompted for the host (machine), select the current host and then click on Continue.
11. Select the appropriate CD-ROM drive as the Media Device, then click on Continue.
12. Depending on the media you are using, the list displayed in the
Install selection window will be different. Double-click on the
appropriate software -- maintenance pack or operating system edition.From the expanded list, select to install the Apache, Mozilla, Secure
Shell (OpenSSH), Perl, and Supplemental Graphics, Web, and X11
Libraries components. You can use the <Ctrl> key to select multiple
components for installation. When all of these components are
highlighted, click on Install.13. When the installation is complete, click on OK.
14. Exit the Software Manager by selecting the Host menu, then Exit.
15. Reboot the machine. (Because the Software Manager relinks the
kernel, you must reboot before the new kernel takes effect.)Highlights of the Maintenance PackChanges and additions provided by this Maintenance Pack include:
+ support for IDE hard disks larger than 137GB+ Hyper-Threading Technology and multi-core support+ cdrtools+ multisession CD read support+ DVD writing with dvdrecord+ updates to the Supplemental Graphics, Web, and X11 Libraries+ X.Org X11 runtime libraries and core fonts+ updates to Perl+ updates to OpenSSH+ updates to the Apache Web Server+ additions to Internet Services: Tomcat and JK+ updates to Mozilla web browser and new plugin support+ updates to MMDF+ CUPS printer subsystem+ GIMP-print support+ ESP Ghostscript+ Foomatic printer drivers+ extended shells+ Vim text editor+ updates to UDK compatibility libraries+ list of problems fixed_________________________________________________________________________
NOTE Drivers for new hardware have been moved out of the
Maintenance Packs and are now available on the Supplement CD.
_________________________________________________________________________Support for IDE hard disks larger than 137GBPreviously, this feature was provided in Maintenance Pack 3 and, before that, in the Update Packs.
Maintenance Pack 4 includes a version of the wd(HW) driver that supports IDE hard disks larger than 137GB.
_________________________________________________________________________
NOTE If you have a new IDE hard disk that is larger than 137GB
that you want to add to your system, you should do so after you
have installed the Maintenance Pack and the new wd driver. If you
want to use the disk as your root drive, you need to load the new
driver at boot time (using the link(HW) bootstring) before
beginning the installation. If your system currently uses an IDE drive larger than 137GB, the
new wd driver makes it possible to use the full capacity of the
disk. To use the entire disk, however, you must manually
reconfigure the drive to recreate the existing disk partitions or
to create new ones. The wd driver readme explains this process in
detail.
_________________________________________________________________________Instructions for installing the wd driver are provided on the SCO web site at:
http://www.sco.com/support/update/download/wddrvr.htmlor the SCO OpenServer Release 5.0.7 Supplement CD Version 4. We strongly
recommend that you review these instructions before using the new
features of the driver.Hyper-Threading Technology and multi-core supportHyper-Threading (HT) Technology was previously part of the Update Packs;
it is now included in Maintenance Pack 4. Hyper-Threading allows two
series of instructions to run simultaneously and independently on a
single Intel(r) HT-enabled processor. With Hyper-Threading Technology
enabled, the system treats a physical processor as two ``logical''
processors. Each logical processor is allocated a thread on which to
work, as well as a share of execution resources such as cache memories,
execution units, and buses.Hyper-Threading Technology can be used on an SCO OpenServer Release 5.0.7 system that is equipped with the following:
+ an Intel Xeon(TM) or HT-enabled Intel Pentium(r) 4 processor+ a chipset that supports HT Technology+ a system BIOS that supports HT Technology_________________________________________________________________________
NOTE By default, Hyper-Threading support is disabled when
Maintenance Pack 4 is installed. The Hyper-Threading support
provided in Update Pack 3 was enabled by default. To enable Hyper-
Threading support after Maintenance Pack 4 is installed, see the
hyperthread(HW) manual page.
_________________________________________________________________________Multi-core support is new in Maintenance Pack 4. A multi-core processor
is a single physical processor that includes two or more ``cores'' and
one or more logical processors per core. Each core acts as a discrete
processor, complete with its own set of execution resources. A dual-core
processor includes two cores, with one logical processor per core. A
dual-core processor that also includes Hyper-Threading Technology
provides two cores and two logical processors per core, allowing the
execution of four simultaneous threads.Maintenance Pack 4 provides support for Intel Xeon and Intel Pentium 4
multi-core processors. SCO OpenServer's multi-core support also requires
a chipset and a system BIOS that support HT Technology._________________________________________________________________________
NOTE Hyper-Threading Technology and multi-core processor support
for SCO OpenServer is provided by the SCO OpenServer Release 5.0.7
Symmetrical Multiprocessing (SMP) product. If you want Hyper-
Threading Technology or multi-core support, the SMP product must be
installed before Maintenance Pack 4. An SMP license is not required to install SMP on a single-CPU
system; simply select to Defer licensing during the installation.
_________________________________________________________________________For more details on Hyper-Threading and multi-core support in SCO OpenServer Release 5.0.7, see the hyperthread(HW) manual page.
CD writer support: cdrtoolsFirst provided in Maintenance Pack 3.Maintenance Pack 4 updates the cdrtools package to version 2.01.01a01. This package is a set of programs for creating CD images (mkisofs) and writing data to recordable/rewritable CDs (cdrecord).
cdrecord(1) 2.01 has been updated to check the CD recorders DMA (Direct
Memory Access) speed and adjust the default burn rate accordingly.
However, SCO OpenServer Release 5.0.7 does not currently support DMA mode
for ATAPI devices; only PIO mode is used. Consequently, you may see a
message similar to:cdrecord: DMA speed to slow (OK for 16x), Cannot write at speed 24x.This message is misleading in that there is not any performance
degradation between this version of cdrecord and the version provided
with Update Pack 3. CD recording continues to run in PIO mode -- a
recording at 24x takes the same amount of time to complete as a recording
at 16x speed.ATAPI DMA support is planned for a future maintenance pack release. cdrecord(1), a port of the ProDVD utility, supports many options and formats that are beyond the scope of basic file archiving. The following sections document the most common tasks for creating data CDs and include information specific to SCO OpenServer Release 5.0.7.
Tested hardwareThe following drives have been tested on SCO OpenServer Release 5.0.7:
Matsushita CW-7502 Philips CDD-2600 Plextor PX-R412Ci Plextor PX-R820Ti Plextor PX-W2412TA Plextor PX-W4824TA Ricoh MP6200S Teac CD-R50S Teac CD-R55S Teac CD-R56S Teac CD-R58S YAMAHA CDRW4416S YAMAHA CRW2260
Most MMC-compliant CD writers should work.ConfigurationIf you have not already used the CD drive to install SCO OpenServer Release 5.0.7, you need to manually configure the drive with the mkdev cdrom command.
Listing available devicesTo display a list of CD devices on the system, use the -scanbus option of the cdrecord(1) command:
cdrecord -scanbusA list of devices similar to this is displayed (SCSI addresses are shown regardless of the controller type):
scsibus0:
0,0,0 0) 'ATAPI ' 'CD-RW 52X24X ' 'MB51' Removable CD-ROM
0,1,0 1) *
0,2,0 2) *
0,3,0 3) *
0,4,0 4) *
0,5,0 5) *
0,6,0 6) *
0,7,0 7) *In this case an ATAPI CD writer is the first device on an IDE controller (address 0,0,0).
cdrecord default file (/etc/default/cdrecord)This file contains the default device settings for cdrecord. First are
the device, speed, and buffer settings (note that the latter two are
commented out):CDR_DEVICE=ide
#CDR_SPEED=40
#CDR_FIFOSIZE=4mThe CDR_DEVICE setting is actually an index into a table with a series of drive-specific defaults:
# drive name device speed fifosize driveropts
#
teac= 1,3,0 -1 -1 ""
panasonic= 1,4,0 -1 -1 ""
plextor= 1,4,0 -1 -1 ""
sanyo= 1,4,0 -1 -1 burnfree
yamaha= 1,5,0 -1 -1 ""
ide= 0,0,0 -1 -1 burnfree
cdrom= 0,6,0 2 1m ""The default entry is ide (as defined by CDR_DEVICE). Because a generic
SCSI driver is used for all CD drives, the SCSI address scheme (host
adapter, device, LUN) is used even with IDE controllers. At the same
time, this scheme only applies to IDE controllers with CD drives (that
is, the numbering of host adapters is not absolute.) For example, on a
system with no SCSI adapters and two IDE controllers, the controller with
the CD drive attached is host adapter 0 (even if it happens to be the
secondary IDE controller)._________________________________________________________________________
NOTE On the command line, the LUN (0) can be omitted (as it is in
the examples discussed here).
_________________________________________________________________________Note the default addresses for other drives are not realistic; be sure
and change the device address in second column to match the actual drive
settings. The other columns (speed, buffer size, and driver options) can
be set as desired. A value of -1 indicates that the device uses its own
default value. The quotes in the column indicate an empty option list;
burnfree allocates a larger buffer for write operations (if supported by
the drive). Other options are documented in cdrecord(1).Creating a data discBefore using cdrecord to make a data disc, you must first create an ISO
image with mkisofs. This sample command creates an ISO9660 image of the
working directory (.) with Joliet (-J) and RockRidge (-r) directory
entries and stores it in the file /tmp/cdimg.iso:mkisofs -r -J -o /tmp/cdimg.iso .To write this image to a disc, you would use a command like this:
cdrecord -v -eject dev=0,0 /tmp/cdimg.isoThe -v is optional and generates verbose output. The dev= argument can
also be omitted if the default drive is defined in /etc/default/cdrecord.
The -eject option ejects the disc when the process is complete. In
addition, cdrecord displays a nine-second countdown to give you an
opportunity to abort the command.You can also perform a test burn using the -dummy option:
cdrecord -v -dummy /tmp/cdimg.isoThe command is executed as specified, but the laser is not activated.
_________________________________________________________________________
NOTE The -dummy option may actually damage media on certain older
drives (rendering them unusable).
_________________________________________________________________________If the system is relatively idle (with little or no disk activity), it is possible to skip creating the image and pipe the output of mkisofs directly to cdrecord:
mkisofs -r /usr/home/cforbin | cdrecord -In this example, the contents of /usr/home/cforbin is written to the disc (the - argument takes data from the standard input).
_________________________________________________________________________
WARNING On active systems you should create an ISO image for best
results.
_________________________________________________________________________Mounting a discYou can mount and unmount a disc from the desktop using the MountCD icon, or from the command line as in these examples using /mnt as a mount point:
mount -r /dev/cd0 /mnt
umount /mntMedia supportcdrecord supports the following drive types/media:______________________________________________________________
Media Type Read-Write Behavior
______________________________________________________________
CD-R Existing data cannot be erased or overwritten
Additional sessions can be appended
CD-RW Entire disc can be erased/blanked
Explicit erasing/blanking required before rewrite
Additional sessions can be appendedMultisession supportTo create multisession disks, you must use the -multi option to leave the CD open (un-fixated) for writing additional sessions:
cdrecord -multi image.isoTo finalize a CD (making it non-writable), simply omit the -multi option.
Writing a new session on a CD normally hides the previous session from
view (requiring an application that allows you to select the active
session). However, it is possible to import the TOC (table of contents)
from the previous session and make the previously-written data available
in the ISO image for the new session.In this example, mkisofs uses the -C option to execute the cdrecord -msinfo command on the specified drive (-M 0,0) to read the location of the previous session and uses the response to create the ISO image:
mkisofs -r -J -C `cdrecord -msinfo` -M 0,0 -o image.iso /usr/home/colossusWhen cdrecord is used to write the image to CD, all the previous data will be accessible along with the new files (in this example, from /usr/home/colossus).
Multisession support: mount(ADM)First provided in Maintenance Pack 3.The mount(ADM) command includes options to mount CD filesystems by
session or sector. See the mount(ADM) manual page for details.By default, the mount(ADM) command mounts the last session. To override
the default and mount the first session, use the syntax in this example:mount -o session=1 /dev/cd0 /mntAt this time, only the first and last sessions can be mounted by session
number. However, the sector option can be used to mount an arbitrary
session by the starting sector number. On newer drives, you can use the
-toc option of the cdrecord(1) command to obtain the starting sector:cdrecord -tocFor a multi-session CD, the output looks something like this:
track: 1 lba: 0 ( 0) 00:02:00 adr: 1 control: 4 mode: 1
rack: 2 lba: 20235 ( 80940) 04:31:60 adr: 1 control: 4 mode: 1
rack: 3 lba: 39262 ( 157048) 08:45:37 adr: 1 control: 4 mode: 1
rack:lout lba: 53507 ( 214028) 11:55:32 adr: 1 control: 4 mode: -1You can use the lba output to mount the desired sector. In this example, the command mounts session 2, which starts at sector 20235:
mount -o sector=20235 /dev/cd0 /mnt_________________________________________________________________________
NOTE If you used cdrecord(1) when it was provided on the Skunkware
CD (and multisession CD read support was not present in SCO
OpenServer Release 5.0.7), note that the the last session is now
mounted by default. Multisession CDs typically include files from
previous sessions by reference, so this should yield a better view
of the contents of the disc.
_________________________________________________________________________DVD writing with dvdrecordPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
Maintenance Pack 4 includes DVD writing support with the dvdrecord(C) command, a port of the ProDVD utility.
Because the industry standard for writing DVDs is SAO (DAO) mode, this is
now the only mode supported by dvdrecord. The previously supported TAO
and RAW modes are no longer available for writing DVDs._________________________________________________________________________
NOTE If you have not already used the DVD drive to install SCO
OpenServer Release 5.0.7, you need to manually configure the drive
with the mkdev cdrom command (which also supports DVD drives).
_________________________________________________________________________The command options for dvdrecord are the same as those for cdrecord (see
``CD writer support: cdrtools''). The dvdrecord(C) manual page is
provided (and is maintained) by SCO. It contains basic information on
creating DVD and CD data discs and includes key examples. The
cdrecord(1) manual page is the generic documentation provided with the
free software and is not specific to SCO UNIX operating systems. Refer
to cdrecord(1) for the complete option set and information on creating
specialized disc layouts and formats.DVD writers testeddvdrecord has been reported to work with most DVD drives. The following
drives have been tested on SCO OpenServer Release 5.0.7:+ Pioneer DVR-A06+ Sony DWU-14A+ Plextor PX-708AUpdates to the Supplemental Graphics, Web, and X11 Libraries
First provided in Maintenance Pack 1.Maintenance Pack 4 includes the following changes in the Supplemental Graphics, Web, and X11 Libraries (GWXLIBS):
+ pkg-config updated to version 0.19+ BerkeleyDB updated to version 4.3.28+ Sablotron updated to version 1.0.2+ xerces updated to version 2.7.0+ OpenLDAP updated to version 2.2.28+ glib 2.x updated to 2.8.1+ pango updated to 1.10.0+ ATK updated to 1.10.1+ cairo 1.0.0 added+ freetype updated to version 2.1.10+ ICU updated to version 3.4+ libgsf updated to version 1.12.3+ libIDL updated to 0.8.6+ mm updated to version 1.4.0+ librsvg updated to version 2.12.0+ libtiff updated to version 3.7.4+ libwmf updated to version 0.2.8.4+ libxml2 updated to version 2.6.22+ libxslt updated to version 1.1.15+ XMLSEC updated to version 1.2.9+ NetPBM updated to version 10.26.14+ PCRE updated to version 6.4+ GNU gettext updated to version 0.14.5+ cURL updated to version 7.14.1+ libexif updated to version 0.6.12+ libexif-gtk updated to version 0.3.5+ tcltools updated to version 1.4 which includes:- Tcl 8.4.10- Tk 8.4.10- Expect 5.43- TclX 8.3.5+ zlib updated to version 1.2.3X.Org X11 runtime librariesFirst provided in Maintenance Pack 3.Maintenance Pack 4 updates the X.Org X11 runtime libraries, header files,
and core fonts to Release 6.8.2. Note that these libraries are now part
of the Supplemental Graphics, Web, and X11 Libraries and no longer a
separate package.The manual pages for the X.Org routines are also installed on the system, but are not included in the MANPATH environment variable. (This is done to avoid collision with the existing X11R5 man pages.) If you wish to access the X.Org manual pages instead of those for the X11R5 server, insert /usr/X11R6/man into your MANPATH variable (or the system-wide setting in /etc/default/man) before the /usr/man entry, as in this example:
MANPATH=scohelp:/usr/X11R6/man:/usr/man:/usr/gnu/man:/usr/local/manIf you add the X11R6 path to /etc/default/man, you should also update the man page database by executing the following command as root:
/usr/man/bin/makewhatis /usr/X11R6/man/*Updates to PerlThe Perl component in Maintenance Pack 4 has been updated to version
5.8.7. This updated version includes a vast number of upgraded Perl
modules. Additionally, this version of Perl has been recompiled to take
advantage of the updated GWXLIBS component.Updates to OpenSSHOpenSSH is updated to version 4.2p1 in Maintenance Pack 4.
In this new version, long passwords (longer than eight characters) are
now supported. Previously, only the first eight characters of a password
were recognized.Note that if your SCO OpenServer system was installed with either the Low
or Traditional security profiles, you need to activate the OpenSSH long
password support. To do this, run the following command:# usermod -D -x "{passwdSignificantSegments 2}" <username>Updates to the Apache Web ServerMaintenance Pack 4 includes the following changes to the Apache Web Server component:
+ Apache Web Server updated to version 1.3.33+ PHP updated to version 4.4.0+ entire suite recompiled to take advantage of the updated Perl and
GWXLIBS componentsAdditions to Internet Services: Tomcat and JKFirst provided in Maintenance Pack 3.The following Internet Services are included in Maintenance Pack 4:
+ Apache Tomcat Servlet Container 4.1.31: an open source package that provides a container for JavaServer Pages(TM) and Java(TM) Servlets. Requires the Java 2 JRE and Java SDK (1.3.1 or 1.4.2).
+ JK: a plugin that replaces mod_jserv and handles the communication
between Tomcat and Apache.Consult the DocView Internet Services page (http://localhost:8457/en/Navpages/Internet.html) for documentation links relating to these packages.
Tomcat notesThe following sections include additional information about Tomcat.
Enabling TomcatAfter installing Tomcat, you must enable it manually. To enable and
start Tomcat, run these commands:/etc/init.d/tomcat enableWhen enabled, Tomcat also automatically restarts each time the system is rebooted.
Tomcat web applicationAfter startup, the default web applications included with Tomcat are available by browsing:
http://localhost:8080/The administrator application is available directly at:
http://localhost:8080/admin/login.jspThe logins for the admin and other roles must be set up as described in the next section.
Using the Tomcat admin and manager loginsBy default the admin and manager web logins are not enabled. To add
these logins, do the following:1. Edit the configuration file /usr/lib/apache/tomcat/conf/tomcat-
users.xml. The contents are similar to the following:<tomcat-users>
<user name="tomcat" password="tomcat" roles="tomcat" />
<user name="role1" password="tomcat" roles="role1" />
<user name="both" password="tomcat" roles="tomcat,role1" />
</tomcat-users>2. You can change these entries to include the desired web login,
password, and the role to which you want them assigned. (Do not
confuse these "web" logins that are used to access the
administrative web application with operating system system logins.)
The admin and manager roles/logins allow someone with the proper
password to run the admin and manager web applications. For
example, the following entries create admin and manager web logins
with tomcat as the password:<role rolename="admin"/> <role rolename="manager"/> <user username="admin" password="tomcat" roles="admin"/> <user username="manager" password="tomcat" roles="manager"/>
3. After making changes or additions, you must restart Tomcat:/etc/init.d/tomcat restartTomcat web application Java exception errorIf you log into the Tomcat Application Manager, stop an Application, restart it, then proceed to the application path and then use the Back button to return to the Tomcat Web Application Manager, the following error may be displayed in the Messages box of the Tomcat Application Manager:
FAIL - Application at context path /tomcat-docs could not be started
FAIL - Encountered exceptionjava.lang.IllegalStateException:
standardHost.start /tomcat-docs: LifecycleException: Container
StandardContext[/tomcat-docs] has already been startedThis is not a fatal error and is not unique to SCO OpenServer Release
5.0.7 systems. The workaround is to use reload instead of stop or start.Updates to Mozilla web browser and pluginsFirst provided in Maintenance Pack 3.Maintenance Pack 4 updates the Mozilla web browser to version 1.7.12.
MozPlugger 1.7.3 replaces the Plugger 5.0 plugin that was provided in
Maintenance Pack 3. MozPlugger is a general purpose multimedia plugin
for Mozilla that supports the display of media files within the browser.MozPlugger is configured to use xpdf 3.0.1 (also provided in Maintenance
Pack 4) to display PDF documents in Mozilla. Additionally, Mozilla is
pre-configured to work with the Java plugin provided on the SCO
OpenServer Release 5.0.7 Supplement CD Version 4.The SCO OpenServer Release 5.0.7 Skunkware Download area (ftp://ftp2.sco.com/pub/skunkware/osr5/vols/) contains many packages providing multimedia support that can be configured in MozPlugger.
Mozilla and the XSENDER commandThis release of Mozilla is configured to enable mail authentication via
the XSENDER command. If your POP server does not support the XSENDER
command and you wish to disable this feature, either edit the system-wide
preferences in /usr/lib/mozilla-1.7.12/defaults/pref/mailnews.js and set
the auth_login preferences to ``false'', or add such entries to your
individual Mozilla preferences as described at the following URL:http://www.mozilla.org/unix/customizing.html#prefsUpdates to MMDFFirst provided in Maintenance Pack 3.The following sections detail various updates and fixes made to MMDF.
Security fixesVarious buffer overflows, null dereferences, and core dumps that affect
all MMDF binaries have been corrected. All but one of the MMDF binaries
that were setuid root are no longer (they have been improved to make this
unnecessary), reducing the potential for further exploitation. The local
channel delivery program is still setuid root because it must deliver
mail into users' mailboxes and run processes with users' UIDs.Improvements to mmdftailor(F)Three new MMDF general configuration parameters can be set in
/usr/mmdf/mmdftailor: ORPHANAGE, DEADLETTER, and TAGCHARS. See
mmdftailor(F) for more information.Improvements to submit(ADM)Several changes have been made to submit(ADM):
+ Messages can now be submitted with a null return address in protocol
mode. Formerly, a null address for either the return address or a
recipient address resulted in the silent termination of address-list
processing. Address-list parsing is now terminated only by a !, as
per the submit specification.+ Messages with a null return address that bounce are discarded instead
of being sent to the orphanage.+ When messages are submitted with the do-not-return (q) option, a
return address is no longer passed to remote hosts, preventing bounce
messages from being generated.+ relay authorization now correctly interprets aliases that point
offsite, include the addresses of users who have a .forward file that
points offsite, as still being local addresses.+ There is now a "magic" address (@@) which is like any other bad
address except that if it occurs in a .forward file or alias no
complaint to supportaddr is issued. This can be used to prevent mail
from being accepted for certain users, similar to aliasing such users
to a nonexistent address but without the notification that is
generated every time a true bad address is referenced. An alias to @@
can itself be used in aliases without generating warning mail, so that
an alias like this can be set up:@@: nosuchuserThen the less cryptic address nosuchuser can be used in aliases and .forward files.
+ Formerly, if -t ("trust me") was given to submit but the user was not
a trusted user, a Source-Info line was added. Now in that case a
Source-Info line is added only if the user is not who they claim to be
in the most authoritative From/Sender field. For the purpose of this
test, a plain Sender is taken to be more authoritative than a plain
From. If a Resent-, Remailed-, or Redistributed- version of either a
From or Sender field is given, it is taken to be more authoritative
than the plain version of either. All such Re* headers are taken to
be equally authoritative, and the last one seen in the header (the one
furthest down in the header) is taken to be most authoritative. To
determine if the user is who they claim to be, the local-address part
of the most authoritative sender is looked up in the password file to
map it to a UID, and that UID is compared to the invoking UID. If the
UIDs match and the hostname part of the address is a name for the
local system, the user is who they claim to be.+ A new parameter, S, indicates to use a Sender: field instead of a
Source-Info: field, and also causes conflicting Sender: fields in the
submitted header to be elided.+ Both lower and upper case characters are now used in queue file names
and message-IDs. This allows up to 2704 messages to be queued by a
single instance of submit. submit will refuse to accept further
messages after that point. submit previously would use only lower
case letters, and would use non-ASCII characters after those ran out.Improvements to the local delivery channel: maildelivery(F)The following changes have been made to maildelivery(F):
+ Messages piped into processes via pipe aliases or the "Pipe" action in
a user's .maildelivery file are now prefixed with a "From" header.
This is important for various mail-processing applications, like
procmail, elm's filter, and mailman. Any workarounds (like preline)
that add a pseudo-"From " line should be removed.+ Variables (like $(address), $(sender), and $(reply-to)) used in
.maildelivery Pipe actions that expand to nothing are now replaced
with an empty argument instead of being elided.Improvements to the smtp channelThe following changes have been made to the smtp channel and are documented in the newly added smtp(ADM) and smtpd(ADM) manual pages:
+ Interpretation of SMTP response codes is now compliant with RFC1123.
All 5xx codes are taken to be indications of permanent failure.
Failure codes in the initial greeting message and in the response to a
HELO are recognized.+ The port number given for smtp in /etc/services will be used. The
default is 25.+ Two new timing parameters control the behavior of the smtp channel
when connecting to a remote SMTP server to deliver an outbound
message:- open_timeout- 220_timeoutSee the smtp(ADM) manual page for more information.
+ Per RFC2505, the SMTP channel can be configured to reject messages
with a return address (envelope sender) that contains a domain name
that does not resolve in a manner that would allow mail to be sent to
it, meaning that the message could not be bounced if necessary. This
is done with the vrfy_sender_domain confstr parameter.+ A colon-separated list of hostnames/addresses that should be treated
as though they do not actually exist can be given with the
no_such_domain_hosts confstr parameter. This is used in conjunction
with the vrfy_sender_domain parameter. See the new smtpd(ADM) manual
page for more information.Improvements to the badusers channelThe badusers channel is intended to map usernames on the local host to
the same usernames on a different host. It intentionally strips the
hostname from the recipient address when it does this mapping so that the
destination host will treat the recipients as local users. However, it
is now common for mail systems to be configured to refuse to accept a
recipient address that contains only a user name. If the badusers
channel is used to forward mail to a host that is not under the control
of the same administrator (for example, a host that is doing virtual mail
hosting), this may present a problem. To resolve this, the badusers
channel has two new confstr parameters, keepdomain and defdomain. Refer
to submit(ADM) for more information.Improvements to the uucp channel: rmail(ADM)rmail(ADM) is now executable by group uucp, and not other, to prevent the
authority of the UUCP system to inject messages with any sender name from
being used by local users. It is possible that some extremely old
software expects to be able to use rmail to inject messages locally. If
this is the case, change the mode of /usr/bin/rmail to allow others to
execute it:chmod o+x /usr/bin/rmailImprovements to cleanque(ADM)cleanque(ADM) no longer sends warnings about messages that were queued
with the no-return flag. cleanque also has a new command line option (-
t) that displays the actions it would take on queued messages without
actually doing anything.CUPS printer subsystemPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
Maintenance Pack 4 includes version 1.1.23 of the Common UNIX Printing
System (CUPS). When installed, both the CUPS and standard (SYSV) print
systems are active. Although both systems use the same command names,
the options and behavior differ somewhat (each print system has a
separate set of commands stored in /usr/lib/lp/cups and
/usr/lib/lp/sysv):accept cancel disable enable lp lpadmin lpmove lpr lpstat reject
Both command sets are supported. To make it easier to use the commands,
you can define the default command set (SYSV or CUPS) to be used when a
print command (such as lpstat) is entered on the command line. This can
be done in any of three ways:+ on a system-wide basis in /etc/default/lpd. The default entry is for
the SYSV print system:PRINT_SYSTEM=SYSV+ on a per-login basis by including PRINT_SYSTEM=CUPS or
PRINT_SYSTEM=SYSV in the environment.+ by including --sysv or --cups as the first argument in the print
command line (example: lpstat --sysv -t).When the pathname is not supplied, the commands from the default print
system are executed. You can use the full pathname to run a command
belonging to the non-default print system. In a similar way, you can
access the manual pages for the two printer systems by supplying the
relevant section name in the man(C) command (1 or 8 for CUPS man pages, C
or ADM for the SYSV man pages):Command CUPS SYSV
_____________________
accept 8 ADM
cancel 1 C
disable 8 C
enable 8 C
lp 1 C
lpadmin 8 ADM
lpmove 8 ADM
lpr 1 C
lpstat 1 C
reject 8 ADMThe CUPS package installs the following online documentation -- the Overview of the Common UNIX Printing System, CUPS User's Manual, Software Administrator's Manual, and CUPS Security Report.
CUPS AdministrationThe CUPS distribution includes a web-based administrative interface that is configured on port 631 (http://localhost:631).
_________________________________________________________________________
NOTE You may have trouble logging in as root to the CUPS web
administrative interface if each of the following three conditions
are true:1. Your system was installed with a Traditional or Low security
profile.2. You set a root password longer than eight characters during
installation.3. The root password has not been changed since installation. In this case, use the passwd(C) command to re-enter the existing
root password or change the password to a different value.
_________________________________________________________________________A list of available printers is generated at the time the CUPS print
daemon (cupsd) is started (when the system enters multiuser mode). To
regenerate the list (such as after connecting a new USB printer), enter
the command:/etc/init.d/cups restart_________________________________________________________________________
NOTE Do not change the configuration for a printer (such as dpi)
while it is printing. This has been known to corrupt the output of
the print job.
_________________________________________________________________________CUPS and Remote Printing (LPD)Although CUPS supports LPD as both a server and a client, the CUPS LPD
server implementation does not support access control (based on the
settings in the /etc/hosts.equiv and /etc/hosts.lpd files). If your
setup requires the use of the standard LPD, or you wish to use access
control, do not install CUPS._________________________________________________________________________
WARNING If you have never run mkdev rlp and you wish to do so, the
CUPS package must be removed before running mkdev rlp and then
reinstalled after remote printing is configured.
_________________________________________________________________________Using CUPS as an LPD clientTo configure CUPS so that jobs can be sent to a remote LPD printer, add a printer via the CUPS administrative interface and use the following settings:
Attribute Setting
_________________________________________________
Device LPD/LPR Host or Printer
Prototype device URI lpd://hostname/printername
Model/driver Raw_________________________________________________________________________
NOTE If the printer was already configured for remote printing,
the host and printer name are present in the /etc/printcap file.
_________________________________________________________________________Using CUPS as an LPD serverTo configure CUPS so that remote hosts can send jobs to the CUPS printing
system on the local host using the LPD protocol, follow the instructions
found in the ``Printing to LPD Servers'' section of the Software
Administrator's Manual in the online CUPS documentation._________________________________________________________________________
WARNING Because only one service can listen for print requests on
the LPD port, mkdev rlp must not be configured on the local host.
If mkdev rlp has ever been run on the host, it must be run again
either before CUPS (MP4) is installed or with CUPS temporarily
removed as described previously. If you intend to use CUPS as an
LPD server you should run mkdev rlp to de-configure remote printing
before CUPS/MP4 is installed (this is because the CUPS
configuration is lost when the package is removed).
_________________________________________________________________________CUPS lpstat(1) commandThe CUPS lpstat(1) always reports the state of devices as having been
last modified on January 1st at 00:00. For example:Obie accepting requests since Jan 01 00:00This is because the CUPS version of lpstat does not capture this
information. The default date is generated so that applications that
parse lpstat output will not fail.CUPS and HP LaserJet 6 Printers (PCL)There is a known problem with the default printer driver displayed in the
CUPS administrative interface for the HP LaserJet Series PCL 6. You
should instead select one of these drivers that are reported to work:+ HP LaserJet Series CUPS v1.1 (en)+ HP LaserJet 6 series, CUPS+Gimp-Printv4.2.5 (en)GIMP-Print supportPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
Maintenance Pack 4 provides the GIMP-Print (4.2.5) printer drivers for
use exclusively with the CUPS printing system. GIMP-Print rasterizes bit
images for printers that do not have built-in rasterizers (including many
of the more inexpensive USB printers on the market).The GIMP-Print package installs the following online documentation -- the GIMP-Print User's Guide and GIMP-Print, The Print Plugin for the GIMP.
ESP GhostscriptPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
Maintenance Pack 4 includes the 7.07.1 release of ESP Ghostscript. This is installed by default in conjunction with GIMP-Print to provide better printer support with CUPS.
Foomatic printer driversPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
The foomatic package contains a generic printer filter and PPD
(PostScript Printer Definition) files for over 200 non-PostScript
printers. The filter and PPD files are integrated with the CUPS package
and cannot be used with the System V LP print system. (Note that the
CUPS package also provides its own PPD files. For more information, see
the Printing topic in the online documentation.)Further documentation on the printers supported by foomatic is available at:
http://www.linuxprinting.org/printer_list.cgiYou can search this site for the proper driver name for your printer, then look for the driver in the Make/Model selection list displayed by the CUPS graphical interface.
Foomatic is also a standalone system that creates PPD files from an XML
database and includes tools for direct printing. The PPD creation
program is called foomatic-rip(1) and the database is called foomatic-db.Note that the Foomatic package provides the following manual pages:
foomatic-configure(1) foomatic-gswrapper(1) foomatic-ppd-options(1) foomatic-ppdfile(1) foomatic-printjob(1) foomatic-rip(1) foomatic-perl-data(1) foomatic-compiledb(1) foomatic-combo-xml(1) foomatic-kitload(8) foomatic-preferred-driver(8) foomatic-getpjloptions(8) foomatic-addpjloptions(8)
Extended shellsPreviously, this feature was provided in the Update Packs; it is now included in Maintenance Pack 4.
The latest, stable versions of the GNU Bourne-Again Shell (bash), Z-Shell (zsh), and Extended C-Shell (tcsh) are provided in Maintenance Pack 4. Documentation for each of the shells, including manual pages and texinfo help, is provided when the shells are installed.
GNU Bourne-Again Shell (bash) version 3.0
This popular shell from the GNU Project is a feature-rich shell that
is largely IEEE POSIX P1003.2 compliant. It has most features of
the Korn Shell (ksh) and is well suited to interactive use. Most
existing shell scripts should run correctly with bash.Z-Shell (zsh) version 4.2
This shell is best suited for interactive usage. It has highly
programmable command and filename completion, is most compatible
with the Korn Shell (ksh), and has features that C-shell (csh) users
will find familiar. It also has a full FTP client that you can
access with built-in shell commands, as well as a number of
additional loadable modules. You can extend zsh with other third-
party modules at any time.Extended C-Shell (tcsh) version 6.13
This is a Berkeley C-shell (csh) compatible shell with many
improvements, bug fixes, and command line editing capabilities.
Note that the SCO version of csh behaves differently from other
implementations of csh (including tcsh) in implementation of the ||
and && operators.Vim text editorMaintenance Pack 4 now includes Vim, version 6.3. Vim is a highly
configurable text editor that is intended to increase text editing
efficiency. It is an improved version of the vi(C) editor.See the vim(1) manual page for more information.
Updates to UDK compatibility librariesFirst provided in Maintenance Pack 3.Maintenance Pack 4 includes version 8.0.2b of the UDK compatibility libraries, which contains several fixes to the runtime libraries, including:
+ fixed bad parsing of some special strings in string-to-floating code+ corrected a potential infinite loop in thr_create()+ fixed a memory leak in tzset()List of problems fixedSCO OpenServer Release 5.0.7 Maintenance Pack 4 contains the following bug fixes:
+ Fixed a problem where the Network Client Manager was getting a fatal
error when used by any user other than root.
fz533088+ The DocView URL rewriting rules now handle filenames like
*.html.<language> correctly.
fz529697+ Fixed a problem which first occurred in the 2.0.0Eb version of GWXLIBS
that made Mozilla interpret the "q" key as a tab.
fz533010+ SCO OpenServer Release 5.0.7 MP3 broke /etc/lmcfsd. It has now been
fixed.
fz530299 / erg712716+ Clicking on the "?" on the lower toolbar no longer crashes xpdf.
fz532798+ In the SCOadmin DHCP Server Manager in CHARM mode, Entry -> Add ->
Address Pools was resulting in a hang. This is now fixed.
fz532170+ /usr/sbin/menu no longer dumps core with a simple menu screen.
fz532986+ Parallel printer polling mode now works.
fz532780 / erg712891+ In CHARM mode it is now possible to add hosts to the /etc/host file
using the SCOadmin Network Client Manager.
fz530820+ Enabling kprf (kernel profiling) on an SMP system was causing a panic.
This has been fixed.
fz528869 / erg712549+ Fixed a problem where the audit daemon was creating files with
permissions set to 000.
fz531480 / erg712842+ A timing race which could cause telnet/rlogin output to hang on an SMP
system was found and fixed.
fz525805+ iknt was fixed so that rlogin now works when iknt is disabled.
fz525874+ General cleanup was done on the relax(ADM) scripts.
fz529525+ cron was fixed so that jobs will not fail when the /etc/default/login
ULIMIT is higher than the kernel default.
fz530027+ ndc(ADMN) was getting a Socket is not connected error on SMP systems.
This was fixed in the socket driver.
fz527413+ A fix was made to telnetd for an intermittent character loss problem.
fz530296+ The spacing between the IP address and the host name was improved in
the Network Client Manager in CHARM mode.
fz530970+ Handling of multiple NICs was improved in the DHCP Client.
fz531650+ Fixed a problem where the SCOadmin Network Client Manager was not
saving the domain search order settings.
fz532183+ Fixed a problem where the SCOadmin Network Client Manager was not
handling the pound sign start-of-comment character in ntp.conf.
fz532302+ The extended shells have been added to the Account Manager shell
selection options.
fz528748+ An escape sequence for changing the color of text displayed on the
console was not working; this has been fixed.
fz530387 / erg712723+ bash was fixed to process the .inputrc file.
fz531964+ Running the setclk -v command twice in a row would cause the RTC to
jump by the delta from UTC if the /etc/rtc.data file existed. Fixed.
fz530715 / erg712764+ In the Network Client Manager, the display of the ``Comments'' field
in the /etc/hosts option was improved.
fz531269+ The SCSI configuration viewing utility (/usr/bin/rview) provided with
the Tricord ES5000 (iiop) HBA driver has been changed to
/usr/bin/iiop_rview to prevent a conflict with an export from the Vim
package. The iiop(HW) manual page has been updated with the new
utility.
fz532889+ dfspace(C) was fixed to show information for all mounted filesystems.
fz530011+ Various programs which use sockets in non-blocking mode, such as ndc
and Postfix, would cause these kernel messages to appear on SMP
systems:WARNING: soreceive: unexpected message type x00000083 WARNING: soreceive: not M_DATA, found 131
This was fixed in the socket driver. fz529156 / fz532437 / erg712795
+ The a15k driver was fixed to not interfere with the ad320 adapter.
fz529926+ Fixes were made for the Dell GX280. See ``Maintenance Pack notes and
limitations'' for more details.
fz530306+ USB devices attached to an EHCI controller sometimes would get a
message logged to the console, Device reset timeout during
enumeration!, even though the USB driver would automatically recover
from the timeout. The driver was fixed to eliminate the unnecessary
message.
fz530377+ A timing race between the fork() system call and the ps(C) command was
found and fixed. It would sometimes cause a newly forked child
process to hang in genfork().
fz532293 / erg712846+ Fixed a memory leak which would occur when opening a message catalog
if the catalog did not start with message number 1.
fz529104 / erg712578+ A fix was made so that the X server display will not be corrupted when
data is written to /dev/console when NSCRN=1 and an ATI video card is
used.
fz529459 / erg712612+ The latest processor errata microcode drop from Intel is included.
fz529620+ A fix was made to the X server function cfbPolyFillRect() to prevent a
core dump.
fz530567 / erg712742+ A buffer overflow in zip has been fixed.
fz530928 / CAN-2004-1010+ A cross-site scripting flaw in htsearch which affected DocView was
fixed.
fz531484 / CAN-2005-0085+ A fix was made to the ip driver for the ``Rose Attack'' vulnerability.
fz529415 / CAN-2004-0230 / SCOSA-2005.9+ A vulnerability in cscope was fixed.
fz530504 / CAN-2004-0996 / SCOSA-2005.11+ A command line buffer overflow in /usr/lib/sysadm/termsh, atcronsh,
and auditsh was fixed.
fz527464 / CAN-2005-0351 / SCOSA-2005.15+ A bug which allowed a chroot prison to be broken was fixed.
fz528523 / CAN-2004-1124 / SCOSA-2005.22+ Two vulnerabilities were fixed in the telnet client.
fz531456 / CAN-2005-0469 / CAN-2005-0468 / SCOSA-2005.23+ Multiple vulnerabilities were fixed in libpng.
fz530148 / CAN-2004-0597 / CAN-2004-0598 / CAN-2004-0599 /
SCOSA-2005.30+ A vulnerability was fixed in zlib.
fz530157 / CAN-2004-0797 / SCOSA-2005.30+ Multiple vulnerabilities were fixed in libtiff.
fz531016 / CAN-2004-0803 / CAN-2004-0804 / CAN-2004-0886 /
CAN-2004-0929 / CAN-2004-1183 / CAN-2004-1308 / SCOSA-2005.30+ Multiple vulnerabilities were fixed in bzip2.
fz532328 / CAN-2005-0953 / CAN-2005-1260 / SCOSA-2005.30+ A telnet client vulnerability was fixed.
fz532339 / CAN-2005-0488 / SCOSA-2005.35+ A vulnerability in unzip was fixed.
fz532853 / CAN-2005-2475 / SCOSA-2005.39+ A vulnerability in OpenSSH related to SCP client file corruption was
fixed.
fz529677 / CAN-2004-0175+ Multiple vulnerabilities were fixed in PHP.
fz529882 / CAN-2004-0594 / CAN-2004-0595+ Multiple vulnerabilities were fixed in PHP.
fz530691 / CAN-2004-1018 / CAN-2004-1019 / CAN-2004-1063 /
CAN-2004-1064+ Multiple vulnerabilities were fixed in PHP related to the exif and
fbsql extensions as well as the unserialize(), swf_definepoly() and
getimagesize() functions.
fz532342 / CAN-2005-0524 / CAN-2005-0525 / CAN-2005-1042 /
CAN-2005-1043+ Multiple vulnerabilities were fixed in Perl.
fz531488 / CAN-2004-0452 / CAN-2004-0976 / CAN-2005-0155 /
CAN-2005-0156 / CAN-2005-0077+ A buffer overflow in libtiff was fixed.
fz532776 / CAN-2005-1544+ Buffer overflows in zlib were fixed.
fz532828 / CAN-2005-1849 / CAN-2005-2096 / CAN-2004-0797+ Multiple security issues were fixed in gzip.
fz532855 / CAN-2005-0758 / CAN-2005-0988 / CAN-2005-1228+ A vulnerability was fixed in CUPS.
fz530152 / CAN-2004-0558+ A wu-ftp denial of service issue was fixed.
fz532335 / CAN-2005-0256+ A vulnerability was fixed in cdrecord.
fz530155 / CAN-2004-0806+ Several security vulnerabilities in Squid were fixed.
fz530962 / SQUID-2004:3 / SQUID-2005:1 / SQUID-2005:2 / SQUID-2005:3+ Denial-of-Service issues found in Squid 2.5.STABLE10 and earlier were
fixed.
fz533116 / fz533151 / CAN-2005-2794 / CAN-2005-2796 / CAN-2005-2917+ A Denial-of-Service issue found in Squid 2.5.STABLE11 and earlier was
fixed.
fz533254 / CVE-2005-3258Maintenance Pack 3 included the following bug fixes:
+ fdisk(ADM) no longer writes the partition table with the kernel cached
copy when just viewing the table.
fz529555+ Fixed a security vulnerability caused by a misconfiguration of the
Apache server that allowed remote users to view any publicly readable
file.
fz528125/erg712368/CAN-2003-0658/CSSA-2003-SCO.16+ A series of vulnerabilities in the SSL/TLS library that could allow
DOS attacks were addressed in OpenSSL 0.9.7d.
fz529412/CAN-2004-0079/CAN-2004-0112/CAN-2004-0081
+ Fixed a problem where the ct utility failed to display a login prompt
after dialback.
fz300580+ uucpd(ADMN) now accepts other paths for uucico and now logs login
successes/failures via syslog.
fz529101+ uucico(ADM) no longer dumps core on large files when using t protocol
over satellite connection.
fz527175+ When creating a filesystem name longer than 7 characters in divvy(ADM)
during install or after install, all the letters after the 7th would
appear in the FS TYPE column. This has been fixed.
fz528538+ The netconfig "Add new LAN adapter" option no longer displays LAN
cards that are already configured.
fz527523/erg712306+ Fixed problem where Xsco failed to start properly with non-C locales
with certain graphics chips.
fz528991+ Support for the X authorization protocols has been added for X
sessions that are not started by scologin.
fz520452/erg712002/CAN-2004-0390/SCOSA-2004.5+ smtpsrvr de-referenced a null pointer and core dumped in response to
certain DNS failures when attempting to resolve the source hostnames.
This has been fixed.
fz527610+ The shutdown(ADM) utility once again displays times in a meaningful
format.
fz529090+ mailx(C) would hang if execmail died unexpectedly. This has been
fixed.
fz529102+ A fix was made to prevent a potential panic in getsockopt().
fz528029+ setcontext() now restores the EDX register correctly.
fz528232+ A buffer overflow with the Xsco -co option has been fixed.
fz520528/erg712006/CAN-2002-0155/CSSA-2003-SCO.26+ uudecode(C) now checks if the specified output is a symlink or pipe.
fz527541/erg712054+ A panic lock timeout from vdsendbuf+53 during vdisk repair was fixed.
fz527937/erg712320+ Several buffer overflows were fixed in the processing of the
font.alias files in Xsco(X).
fz528866/erg712547+ A problem where the X server would allow access to any shared memory
on the system has been fixed.
fz520242 / erg711972 / CAN-2002-0164 / CSSA-2003-SCO.26+ A problem in the SCO Internet Manager (mana) that let local users gain
root level privileges was fixed.
fz528244 / erg712420 / CAN-2003-0742 / CSSA-2003-SCO.19+ Multiple buffer handling problems were fixed in OpenSSH.
fz528324 / erg712436 / CAN-2003-0693 / CAN-2003-0786 / CAN-2003-0695 /
CAN-2003-0682 / CSSA-2003-SCO.24+ A number of security issues were fixed in Apache.
fz527514 / erg712258 / fz528422 / erg712464 / fz528484 / erg712486 /
fz528487 / erg712489 / fz527929 / erg712354 / CAN-2003-0192 / CAN-
2003-0542 / CAN-2002-1396 / CAN-2003-0166 / CAN-2003-0442 / CSSA-
2003-SCO.28+ Several security issues were fixed in the OpenSSL and zlib components
of gwxlibs.
fz528382 / erg712448 / fz527506 / erg712256 / fz527489 / erg712252 /
CAN-2003-0543 / CAN-2003-0544 / CAN-2003-0545 / CAN-2003-0131 / CAN-
2003-0107 / CSSA-2003-SCO.29+ A cross-site scripting vulnerability in the CGI.pm perl module was
fixed.
fz528215 / erg712409 / CAN-2003-0615 / CSSA-2003-SCO.30+ Various buffer overflows and other security issues were fixed in MMDF.
fz528322 / erg712434 / SCOSA-2004.7+ pmwm and mwm(XC) were fixed to allow the key binding for <Ctrl>-
<Alt>-<Shift>-1 to be changed or disabled.
fz528631 / erg712515+ A system hang was fixed. It was caused by strd looping and trying to
allocate memory for message headers when the mblock table was full.
fz527661 / erg712281+ A number of security issues were fixed in Mozilla.
fz528708 / erg712531 / SCOSA-2004.8+ getty(M) now includes a -r option that prevents it from dropping DTR
and resetting the termio modes at startup. This was the default
behavior in OpenServer 5.0.6 but it was changed in OSR5.0.6a. The -r
option can be used to revert to the OpenServer 5.0.6 behavior. Some
third-party applications wait for incoming calls, initialize the
termio parameters, and then invoke getty to initiate a login session.
In this case, to avoid dropping connections when getty is invoked, the
-r option should be used by editing both /etc/inittab and the
appropriate file under /etc/conf/init.d (for standard serial ports,
this would be /etc/conf/init.d/sio) and adding the -r option to the
getty lines that should have their behavior modified.
fz527207 / erg712222Maintenance Pack 1 included the following bug fixes:
+ A remotely exploitable off-by-one bug was fixed in the wu-ftp FTP
sender.
fz528115 / erg712363 / CAN-2003-0466 / CSSA-2003-SCO.20+ A problem that prevented kernel builds from succeeding if $ROOT was
longer than 60 characters has been fixed.+ The licensing system has been corrected so that the brand(ADM) command
now recognizes pre-Release 5.0.7 User and CPU licenses. In addition,
the Licensing Policy Manager Daemon (sco_pmd) has been fixed so that
system restores now correctly restore the SCO System ID. This fix
makes the OSS646 supplement obsolete and unnecessary.
fz527794+ A panic was corrected in the HTFS filesystem driver. This panic
sometimes occurred when mounting an AFS, EAFS, or HTFS filesystem with
less than 42Kbytes of free space.
fz527790+ A problem on USB keyboards where typed characters sometimes repeated
has been fixed. This problem tended to occur on IBM(r) Blade servers
with a built-in AT-to-USB keyboard adapter.
fz527743+ Fixed a null dereferencing problem in MMDF.
fz527660+ Changed MMDF format specs so that the date registered in email headers
is padded with a leading zero if the message is sent in a single-digit
hour (between 1:00 and 9:00). This addresses the problem of some
anti-spam applications assigning high spam scores to messages simply
because the format of the hour in the date header does not match the
applications' good-date-header test, which expects hours to be
represented in double-digits.+ Fixed a security vulnerability in the sendmail binary that could be
exploited by remote users to gain root access.
fz527482/erg712245/CSAA-2003-SCO.6+ The chmod(C) command was modified so it does not apply changes to
files if permissions are already correct. This modification may
significantly improve performance, especially over an NFS mount, of
commands like:chmod -R +r /data+ The crontab(C) command has been corrected to always exit with an error
status if it fails, or zero (no error) status if it succeeds.
fz300043+ Fixed the ps(C) command so the -o pcpu option reports an accurate
value.
fz527713+ A problem was corrected which caused uudecode(C) to dump core when
decoding from standard input.
fz527731+ A buffer overflow in the wordwrap() function in releases of PHP
previous to version 4.3.0 and later than version 4.1.2 has been fixed.
Under certain circumstances, this buffer overflow created a security
vulnerability.
fz527514 / erg712258+ Fixed a security vulnerability where a TCP/IP socket could become
permanently stuck in a SYN_SENT state, thereby making the system
vulnerable to a denial-of-service attack.
fz526775 / erg712173 / erg711405+ The problem of data transfers not always working if the FTP daemon was
configured in /etc/services to run on a non-standard port or if the
daemon was invoked with the -P argument has been fixed.
fz527753+ The telnetd(ADMN) command now has a -r option to specify which
pseudo-terminals (ptys) to use, which is useful in the following
situations:+ Restrict telnetd to using ptys in a given range, so that other ptys
can be dedicated to other functions.+ Assign a telnetd that is bound to a particular non-standard port a
specific pty so that a login on that port will always get the same
pty name (as required by some older applications created when
hard-wired serial terminals were the norm).See telnetd(ADMN) for more information.
fz527717 / erg712178+ Integer overflow vulnerabilities were corrected in SUNRPC adr_array(),
xdrmem_getbytes(), and related functions. Theoretically, these
vulnerabilities could be exploited to gain a privilege escalation.
fz525724 / fz526830 / erg501641 / erg712178 / CA-2002-25 / CAN-2002-
0391 / CAN-2003-0020+ A buffer overflow in BIND that could lead to security vulnerabilities
has been fixed.
fz526617 / erg712158 / CSSA-2003-SCO.17 / CAN-2002-1219+ Fixed some minor problems in the PPP Connection Wizard interface.+ Fixed an SMP problem where PCI interrupt sharing was broken when one
or more of the drivers sharing an interrupt was able to handle the
interrupt on any processor. Symptoms of this problem included
spurious and lost interrupts.
fz526928+ Fixed a panic that occurred when booting a system with SMP installed.
The panic occurred most commonly in kmem_alloc() while the
/etc/sysdump -qi /dev/swap -o /dev/swap command was running in a
different process. Typically, this problem was encountered on systems
with large swap areas (around 2.5GB) and the usb_ohci driver enabled.
fz527402+ Fixed a problem that caused the Mylex/BusLogic blc SCSI HBA driver to
fail when booting with SMP installed. The error message produced in
this situation was:WARNING: apic - no BIOS information found for irq IRQ_NUM+ Fixed a number of bugs in SCO OpenServer Development System header
files and tools.
fz527564 / fz527644 / fz527678+ The C Compilation Subsystem (CCS) has been updated to be more strictly gABI compliant. This includes changes to the assemblers, link editors, and startup files to support the special .init_array and .fini_array sections in ELF programs that certain third-party C++ compilers use. fz527038 / fz527718
+ Security vulnerabilities were fixed in BIND.
fz528463 / erg712478 / VU#734644+ Security vulnerabilities were fixed in OpenSSL.
fz529412 / erg712603 / CAN-2004-0079 / CAN-2004-0112 / CAN-2004-0081+ A security issue was fixed in Apache related to mod_digest.
fz528952 / erg712565 / CAN-2003-0987Maintenance Pack notes and limitationsThe following notes and limitations apply to the SCO OpenServer Release 5.0.7 Maintenance Pack 4:
+ Issues associated with running SCO OpenServer Release 5.0.7 on a Dell
OptiPlex GX280 desktop, including problems with using USB devices,
have been addressed through a combination of fixes. These fixes are
available from an updated SCO OpenServer Release 5.0.7 System CD-ROM
and SCO OpenServer Maintenance Pack 4. The updated SCO OpenServer
Release 5.0.7 System CD-ROM has been shipping since 4 October 2005 and
is labeled with the following part number:7OSR01A05073To install SCO OpenServer Release 5.0.7 on a Dell OptiPlex GX280 desktop:
1. Use the updated SCO OpenServer Release 5.0.7 System CD-ROM, with
the part number 7OSR01A05073.At the Boot: prompt, always use the uhcireset bootstring to avoid the possibility of the system hanging when a USB floppy drive is attached to the system.
defbootstr uhcireset2. If the GX280 system contains an IDE controller, you should also
use the most current wd BTLD.defbootstr link=wd uhciresetThe most current wd driver is dated 30 July 2004 and is available on the SCO OpenServer Release 5.0.7 Supplement CD Version 4, as well as the SCO OpenServer Release 5.0.7 Supplements web page (http://www.sco.com/support/update/download/osr507list.html).
3. After the SCO OpenServer Release 5.0.7 installation is complete,
install Maintenance Pack 4.+ On SCO OpenServer Release 5.0.7 Host systems where networking is only
configured for loopback (or network configuration is deferred at
installation), the Apache webserver fails to start. (DocView does
start and appears to be running.)There are two workarounds for this problem:
A. Comment out the following lines in /usr/lib/apache/httpd.conf:LoadModule unique_id_module libexec/mod_unique_id.so
AddModule mod_unique_id.cB. Set the hostname to the loopback address in /etc/hosts:127.0.0.1 yourhostname+ After installing SCO OpenServer Release 5.0.7 Maintenance Pack 4, you
may need to update a few configuration files that are part of the GIMP
Toolkit (GTK+) and necessary for operation of Mozilla. Some of the
path names in the default configuration have changed, but the upgrade
process does not modify these files automatically because you may have
customized them for your own purposes.Each file has a default file in the same directory. For most sites, you can simply copy the new default file to the data file. If you have loaded extra objects into these data directories, you may need to run a special command to produce the correct configuration file. The files affected are:
/etc/pango/pango.modules To regenerate this file if you have added extra modules, use the command pango-querymodules after the upgrade and redirect the output of that program to this file. If you have not added any Pango modules, simply execute:
cp pango.modules.default pango.modules/etc/gtk-2.0/gtk.immodules Regenerate this file using the command gtk-query-immodules- 2.0, or copy the default using the command:
cp gtk.immodules.default gtk.immodules/etc/gtk-2.0/gdk-pixbuf.loaders Regenerate this file using the command gdk-pixbuf-query- loaders, or copy the default file using the command:
cp gdk-pixbuf.loaders.default gdk-pixbuf.loaders/etc/pango/pango.aliases
If you have made changes, you may need to examine the new
default file to see if there are specific changes you want
to merge into your configuration file; otherwise copy the
default file using the command:cp pango.aliases.default pango.aliases/etc/pango/pangorc
If you have made changes, you may need to examine the new
default file to see if there are specific changes you want
to merge into your configuration file; otherwise copy the
default file using the command:cp pangorc.default pangorc/etc/pango/pangox.aliases
If you have made changes, you may need to examine the new
default file to see if there are specific changes you want
to merge into your configuration file; otherwise copy the
default file using the command:cp pangox.aliases.default pangox.aliases/usr/lib/php.ini
This file also has an updated default file named
/usr/lib/php.ini-dist. If you are not an SCO Update Service
customer and you copy the updated file over the existing
php.ini file, please note that PHP will fail to load unless
you comment out the PostgreSQL module. This can be found on
line 552 of the default file:extension=libpgsql.soTo comment out this entry, simply insert a semicolon (;) at the beginning of the line.
+ Previously, the icons in /usr/lib/apache/icons did not display in
Apache because the icon directory and files are symbolic links. This
also prevented test scripts located in /usr/lib/apache/cgi-bin from
running properly. To correct these problems, the FollowSymLinks
option has been added to the /usr/lib/apache/conf/httpd.conf.default
file. If no modifications were made to the original file, you can
copy the default file to /usr/lib/apache/conf/httpd.conf. If you have
customized the httpd.conf file, you must incorporate the change
manually, as shown here:<Directory "/usr/lib/apache/icons"> Options Indexes FollowSymLinks MultiViews AllowOverride None Order allow,deny Allow from all </Directory>
<Directory "/usr/lib/apache/cgi-bin"> AllowOverride None Options FollowSymLinks Order allow,deny Allow from all </Directory>
+ If you did not install MP3 and you completed a backup of your system
prior to installing Maintenance Pack 4, you should refresh the backup
after you complete the installation of Maintenance Pack 4.If you need to restore a system using a backup that was created prior
to the installation of Maintenance Packs 1, 3, or OSS656B, the
Licensing Policy Manager Daemon (sco_pmd) may not start. If you
experience this, log in as root, put the system in single-user mode,
and run the following:brand -B oyrargAfterwards, reboot your system; the sco_pmd daemon will now be able to start.
+ If you encounter a situation where you need to stop the Licensing
Policy Manager Daemon (sco_pmd) -- for example, you are migrating a
system on the network to new hardware and you start receiving
duplicate license violations -- be sure to use the following command
for an orderly shutdown:sco_pmd -sFor more information on sco_pmd, including how to start and stop the daemon, see the sco_pmd(ADM) manual page.
+ Several tunable parameters for the System V Inter Process
Communications (IPC) shared memory and semaphore facilities have been
updated. The default settings were raised to values which should
accommodate most commercial and open source databases without
additional tuning. The maximum values of several parameters were also
raised. The changes increase kernel memory usage by approximately
33K.Installation of this Maintenance Pack raises the default and maximum values of these parameters as follows:
Parameter Previous Previous New default New maximum
name default maximum
___________________________________________________________
SEMMAP 10 - 256 -
SEMMNI 10 - 384 -
SEMMNS 60 - 512 -
SEMMNU 30 100 150 8192
SEMMSL 25 - 50 -
SEMOPM - 10 - 1024
SEMUME - 10 - 25
SHMMAX 524288 - 10485760 -
SHMMNI 100 - 200 -Individual parameters that have already been set higher than these values are not changed.
+ At this time, Arabic and Georgian characters do not display correctly
in the Mozilla web browser.+ If you are viewing the CUPS web-based administration tool (available
from http://localhost:631) in the Mozilla web browser, there is a
problem that prevents you from adding a printer using the Printers
menu in the ESP bar.Instead, use the Do Administration Tasks link on the main page of the
CUPS administration tool. Then click the Add Printer button in the
Printers category. See the online CUPS documentation, available from
DocView, for more details on adding printers.+ Printing to an Epson Stylus C82 printer with CUPS and GIMP-print
results in disjointed print-outs and many blank pages. A fix for this
problem will be available in a future release.