Technical article 125205

SCO OpenServer Release 5.0.7 Update Pack 1 Release and Installation Notes

OpenServer 5.0.7

Written · Last revised

Problem

SCO OpenServer Release 5.0.7 Update Pack 1 Release and Installation Notes

Solution

What follows are the Release and Installation notes for SCO OpenServer Release 5.0.7 Update Pack 1. For Release and Installation Notes in ASCII, HTML and PDF format please see:

http://www.sco.com/support/update/download/osr507up.html
-----------------------------------------------------------------------------

SCO OpenServer Release 5.0.7 Update Pack 1 Release and Installation Notes

-----------------------------------------------------------------------------

This document provides installation instructions and new feature descriptions for SCO OpenServer(TM) Release 5.0.7 Update Pack 1.

These Release and Installation Notes contain critical information that
you need to know before and after installing SCO OpenServer Release 5.0.7
Update Pack 1.  Familiarize yourself with the information that is
relevant to your system, then install the Update Pack according to the
instructions in this document.
_________________________________________________________________________
   NOTE  Unless otherwise noted, this document supplements the SCO
   OpenServer Release 5.0.7 Late News, which are still relevant.  As
   information becomes available after the publication of these
   Release and Installation Notes, it is added to the SCO OpenServer
   Release 5.0.7 Late News document, available from the SCO web site
   at:
http://www.sco.com/support/docs/openserver
_________________________________________________________________________

These Release and Installation Notes cover the following topics:

+  Before installing the Update Pack
+  Installing the Update Pack
   -  Installing the Update Pack using SCO Update
   -  Installing the Update Pack from downloaded media images
   -  Installing the Update Pack across the network
+  Removing the Update Pack
+  New features in the Update Pack
   -  Support for IDE hard disks larger than 137GB
   -  Extended shells
   -  Info-ZIP
   -  Hyper-Threading Technology
   -  New manual pages
Before installing the Update Pack
---------------------------------

Before you can install SCO OpenServer Release 5.0.7 Update Pack 1, you must:

1.  Install the SCO OpenServer Symmetrical Multiprocessing (SMP)
    product if you want to use Hyper-Threading Technology.
    This product must be installed before Maintenance Pack 1
    and Update Pack 1.
2.  Install Maintenance Pack 1 on your SCO OpenServer Release 5.0.7
    system.

See the SCO OpenServer Release 5.0.7 Maintenance Pack 1 Release and Installation Notes for installation information.

3.  Install the SCO Update Service (SUS) Enabler license.

This license is available in two forms:

+  the SCO OpenServer Release 5.0.7 with SCO Update bundled product
   includes the SUS Enabler license in the operating system license
+  to supplement the basic SCO OpenServer Release 5.0.7 license, you
   can purchase an add-on SUS Enabler license
________________________________________________________________________
   NOTE  To determine if your SCO operating system is bundled with
   SCO Update, run:
/etc/brand -L | grep 'a120;'

If this command returns output, your operating system license also contains the SUS Enabler license.

   If you do not have an SUS Enabler license, contact your
   software supplier.
________________________________________________________________________
See ``Licensing and registering SCO OpenServer products'' in the SCO
OpenServer Handbook for information on installing licenses using the
License Manager.
4.  Register your copy of SCO OpenServer Release 5.0.7 and/or your SUS
    Enabler license at the SCO OpenServer Registration web page:
http://www.sco.com/registration
See ``Registering SCO OpenServer products'' in the ``About SCO
OpenServer systems'' chapter in the SCO OpenServer Getting Started
Guide for more information on registering products and licenses.
________________________________________________________________________
   NOTE  If you haven't already registered your operating system
   license, you can simply register the SUS Enabler license. The
   operating system license is automatically registered at the
   same time.
________________________________________________________________________
After you register the SUS Enabler license, you will notice that an
additional SCO OpenServer Update Service license is listed by the
License Manager.  This license is automatically generated when you
successfully register with SCO. When you see this license in the
License Manager, it means that the SCO Update service has been
successfully activated.
5.  Back up the data on your system and verify the integrity of the
    backup.

You are now ready to install Update Pack 1.

Installing the Update Pack
--------------------------
   _________________________________________________________________________
      NOTE  Be sure to read ``Before installing the Update Pack'' prior
      to starting this procedure.
   _________________________________________________________________________

There are two ways to acquire and install SCO OpenServer Release 5.0.7 Update Pack 1:

+  directly over the Internet using the SCO Update function in the
   Software Manager.
+  download the Update Pack 1 media images from either the SCO web site
   or FTP site.
You can also install Update Pack 1 from one SCO OpenServer system to
another across a TCP/IP network.  See ``Installing the Update Pack across
the network''.
Installing the Update Pack using SCO Update
The new SCO Update feature of the Software Manager allows you to install
Update Pack 1 over the Internet.  This approach saves you the steps --
and extra hard disk space -- of first downloading installable image files
from SCO's web or FTP sites.
To use SCO Update:
1.  Log in as root.
________________________________________________________________________
   NOTE  You should have rebooted your system after installing SCO
   OpenServer Release 5.0.7 Maintenance Pack 1.  At the very
   least, you need to restart the Software Manager to be able to
   use the new SCO Update functionality.
________________________________________________________________________
2.  Start the Software Manager by double-clicking on its icon on the
    desktop, or by entering the following at the command-line prompt:
scoadmin software
3.  From the Software menu, select SCO Update.  The system connects to
    the SCO Update server.

The Install Selection window displays all of the SCO OpenServer Release 5.0.7 update packs, maintenance packs, drivers, and so forth that are currently available.

4.  Highlight Update Pack 1 and click on Install.

The Update Pack software is automatically downloaded and installed on your system.

5.  When the installation is complete, click on OK.  The Software Manager
    lists Update Pack 1 among the installed software.
________________________________________________________________________
   NOTE  If some of the Update Pack 1 packages were not installed
   because the corresponding software does not exist on your
   system, the Software Manager will show the Update Pack as only
   partially installed.  This is okay.  The Update Pack
   installation is complete for your current system configuration.
________________________________________________________________________
6.  Exit the Software Manager by selecting the Host menu, then Exit.
7.  Reboot the machine, if required. If the Software Manager relinks the
    kernel during the installation, you must reboot before the new kernel
    takes effect.
Installing the Update Pack from downloaded media images

To install Update Pack 1 from media images that you manually download:

1.  Log in as root.
2.  Download the Update Pack 1 media images from either the SCO web site
    or using FTP:
+  to use the SCO web site, go to the SCO Update Service and
   Supplemental Downloads web page for SCO OpenServer Release 5.0.7:
http://www.sco.com/support/update/download/osr507list.html
+  to use FTP, go to the SCO Support Download Area:
https://ftp.scoexpert.com/openserver5/osr507up
Update Pack 1 consists of a number of media image files with names of
the form VOL.000.000, VOL.000.001, and so forth.  Be sure to download
all of the Update Pack 1 media image files.
3.  Start the Software Manager by double-clicking on its icon on the
    desktop, or by entering the following at the command-line prompt:
scoadmin software
4.  From the Software menu, select Install New.
5.  When prompted for the host (machine), select the current host and
    then click on Continue.
6.  Select Media Images as the Media Device, then click on Continue.
    (You may need to scroll down before you see the Media Images option.)
7.  Enter the absolute pathname for the directory that contains the
    Update Pack 1 media images.  For example:
/tmp/507up1
Click on OK.
8.  In the Install Selection window, make sure that the Update Pack is
    highlighted then click on Install.
9.  You are warned if certain packages in the Update Pack will not be
    installed because the software they modify is not installed on your
    system.  Click on Continue.
10. When the installation is complete, click on OK.  The Software Manager
    lists Update Pack 1 among the installed software.
________________________________________________________________________
   NOTE  If some of the Update Pack 1 packages were not installed
   because the corresponding software does not exist on your
   system, the Software Manager will show the Update Pack as only
   partially installed.  This is okay.  The Update Pack
   installation is complete for your current system configuration.
________________________________________________________________________

11. Exit the Software Manager by selecting the Host menu, then Exit.

12. Reboot the machine, if required. If the Software Manager relinks the
    kernel during the installation, you must reboot before the new kernel
    takes effect.
Installing the Update Pack across the network
You can install SCO OpenServer Release 5.0.7 Update Pack 1 from one SCO
OpenServer Release 5.0.7 system onto another across a TCP/IP network.  To
do so, you need a software server, which you can create as described in
``Installing and managing software over the network'' in the SCO
OpenServer Networking Guide.  This server has a user account called
swadmin.
Install or load Update Pack 1 on the software server, using one of the
installation procedures described in ``Installing the Update Pack''.
Also see ``Installing and managing software components'' in the SCO
OpenServer Handbook for more information on loading software.
To install Update Pack 1 onto a local machine once the Update Pack is
available from the software server, start the Software Manager and select
Install New.  In the Begin Installation window, you are prompted for the
source location of the Update Pack.  Select From Another Host.  You need
to provide the name of the software server, as well as the password of
the swadmin user on the software server.
Removing the Update Pack
------------------------

To remove SCO OpenServer Release 5.0.7 Update Pack 1:

1.  Log in as root.
2.  Start the Software Manager by double-clicking its icon on the
    desktop, or by entering the following at the command-line prompt:
scoadmin software
3.  Select Update Pack 1 in the list of installed software.
4.  From the Software menu, select Remove Software.  In the confirmation
    window, verify that you selected the correct software, then click on
    Remove.
5.  When the Removal complete window appears, click on OK. The Software
    Manager should no longer list Update Pack 1.
6.  Exit the Software Manager by selecting the Host menu, then Exit.
7.  Reboot the machine, if required. If the Software Manager relinks the
    kernel during the removal, you must reboot before the new kernel
    takes effect.
New features in the Update Pack
-------------------------------

New features and functionality provided in SCO OpenServer Release 5.0.7 Update Pack 1 include:

+  ``Support for IDE hard disks larger than 137GB''
+  ``Extended shells''
+  ``Info-ZIP''
+  ``Hyper-Threading Technology''
+  ``New manual pages''
Support for IDE hard disks larger than 137GB

Update Pack 1 enables a new version of the wd(HW) driver to support IDE hard disks that are larger than 137GB. The new wd driver is available separately from this Update Pack, either via SCO Update or SCO's web or FTP sites.

_________________________________________________________________________
   NOTE  If you have a new IDE hard disk that is larger than 137GB
   that you want to add to your system, you should do so after you
   have installed Update Pack 1 and the new wd driver. This is
   especially important if you want to use the disk as your root
   drive.  If you add the disk before installing this software, the
   drive will not be configured correctly to use all of its available
   disk space and you will need to recreate the disk partitions or add
   new ones.
   If your system currently uses an IDE drive that is larger than
   137GB, the new wd driver makes it possible for you to now use the
   full capacity of the disk.  To use the entire disk, however, you
   will need to manually reconfigure the drive to recreate the
   existing disk partitions or to create new ones.  The wd driver
   readme explains this process in detail.
_________________________________________________________________________
Instructions for installing the wd driver are provided in a readme file
on the SCO web and FTP sites.  We strongly recommend that you review
these instructions before installing the driver.

The updated version of the wd driver can be installed using the SCO Update feature in the Software Manager.

Or, you can manually download the driver from either the SCO web site or using FTP:

+  to use the SCO web site, go to the SCO Update Service and Supplemental
   Downloads web page for SCO OpenServer Release 5.0.7:
http://www.sco.com/support/update/download/osr507list.html
+  to use FTP, go to the SCO Support Download Area:
https://ftp.scoexpert.com/openserver5/drivers/OSR507/btld
Extended shells

The latest, stable versions of the GNU Bourne-Again Shell (bash), Z-Shell (zsh), and Extended C-Shell (tcsh) are included in this Update Pack. Documentation for each of the shells, including man pages and texinfo help, is provided when the shells are installed.

GNU Bourne-Again Shell (bash)
     This popular shell from the GNU Project is a feature-rich shell that
     is largely IEEE POSIX P1003.2 compliant.  It has most features of
     the Korn Shell (ksh) and is well suited to interactive use.  Most
     existing shell scripts should run correctly with bash.
Z-Shell (zsh)
     This shell is best suited for interactive usage.  It has highly
     programmable command and filename completion, is most compatible
     with the Korn Shell (ksh), and has features that C-shell (csh) users
     will find familiar.  It also has a full FTP client that you can
     assess with built-in shell commands, as well as a number of
     additional loadable modules.  You can extend zsh with other third-
     party modules at any time.

Extended C-Shell (tcsh) This is a Berkeley C-shell (csh) compatible shell with many improvements, bug fixes, and command line editing capabilities. Note that it is not compatible with the SCO version of csh.

Info-ZIP

Update Pack 1 includes the Info-ZIP package, which provides the zip and unzip compressor-archiver utilities. These commands are compatible with the DOS-based PKZIP tools created by PKWARE, Inc.

Manual pages for these commands are also installed on the system.

Hyper-Threading Technology
Update Pack 1 adds support for the Intel(r) Hyper-Threading (HT)
Technology. Hyper-Threading allows two series of instructions to run
simultaneously and independently on a single Intel Xeon(TM) or HT-enabled
Intel Pentium(r) 4 processor.  With Hyper-Threading Technology enabled,
the system treats a physical processor as two ``logical'' processors.
Each logical processor is allocated a thread on which to work, as well as
a share of execution resources such as cache memories, execution units,
and buses.

Hyper-Threading Technology can be employed on a PC that is equipped with the following components:

+  an Intel Xeon or HT-enabled Intel Pentium 4 processor
+  a chipset that supports HT Technology
+  a system BIOS that supports HT Technology
SCO OpenServer supports Hyper-Threading Technology via the SCO OpenServer
Release 5.0.7 Symmetrical Multiprocessing (SMP) product.  When SMP is
installed, Hyper-Threading is enabled by default.
_________________________________________________________________________
   NOTE  If you want to use Hyper-Threading Technology, the SMP
   product must be installed before Maintenance Pack 1 and
   Update Pack 1.
   An SMP license is not required to install SMP on a single-CPU
   system; simply select to Defer licensing during the installation.
_________________________________________________________________________

See the hyperthread(HW) manual page for details on using Hyper-Threading Technology.

New manual pages

Update Pack 1 provides the following new manual pages:

+  hyperthread(HW) -- documents use of the Intel Hyper-Threading
   Technology on an SCO OpenServer system.
+  p6update(HW) -- documents the utility for modifying Intel Pentium
   processor microcode, based on microcode updates provided by Intel
   Corporation.
____________________
Copyright (c) 2003 The SCO Group, Inc.  All rights reserved.
Date:  31 July 2003

From the Xinuos technical article database, record 125205. Reproduced with permission. The original is at www.sco.com/ta/125205, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.