Technical article 110684

The custom+ binary (backend) process has died before showing the installation source devices.

OpenServer 5.0.0OpenServer 5.0.2OpenServer 5.0.4OpenServer 5.0.5OpenServer 5.0.6OpenServer 5.0.7

Written · Last revised

Problem

1. While trying to install a product through the Software
Manager, I select "Software -> Install New...".  A dialog
comes up asking from what host (machine) I want to install.

I pick the name of the local machine and as soon as I select the 'Continue' button, an error message occurs, stating:

The custom+ binary (backend) process has died.

All I can do is select 'OK' which exits the Software Manager.

2. Running in CHARM (character mode) after I pick the name of the local machine, and select the 'Continue' button, nothing happens for a long time. The only sign of activity is asterisks [*** ] on the top, left side of the screen keep scrolling.

Cause

One of the possible causes of this can be that the device information database is corrupt.

Another possible cause for this issue is that the custom.log file has become full, or 2 gigabytes in size.

Solution

To rebuild the device information database, log on to the system as root and change directory to:

/etc/conf/cf.d

Rename the sysRegistry file so that you have a backup of it:

# mv sysRegistry sysRegistry.bak
Create a new one using:
# /etc/conf/bin/idmkreg -d sdevice
Also check the custom.log file in:
/var/opt/K/SCO/SoftMgr/*/custom/
If this file reaches 2 gigabytes in size, then custom is unable to
perform actions.  Redirect /dev/null into the log to clear it.
# cat /dev/null > /var/opt/K/SCO/SoftMgr/*/custom/custom.log

See also

ta105025, "How can I use the Software Manager/custom(ADM) with a non-standard device?"

ta105029, "SCOadmin does not start; there are problems with Backup/Filesystem Managers."

ta105797, "I'm getting floppy read errors with known good media and hardware on OSR5."

ta105864, "How to remove additional hard drive configuration on SCO OpenServer 5.0.4."

ta104978, "idmkreg reports 'error updating space.c for Stp' when the kernel is relinking."

ta105264, "How can I determine why my Software Manager fails to start?"

Manual page idbuild(ADM)

From the Xinuos technical article database, record 110684. Reproduced with permission. The original is at www.sco.com/ta/110684, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.