Technical article 126891

What is Support Level Supplement (SLS) OSS674, the SCO Symmetrical MultiProcessing Update?

OpenServer 5.0.7

Written · Last revised

Problem

What problem is fixed by Support Level Supplement (SLS) OSS674A, the SCO Symmetrical MultiProcessing Update?

Solution

OSS674A fixes a problem which causes some multiprocessor systems to hang during OS initialization if the boot processor is not listed first in the BIOS processor tables.

This problem has been observed on some platforms configured with mixed processor steppings.

Ideally this patch should be IMMEDIATELY applied after SCO Symmetrical Multiprocessing (SCO SMP) and Maintenance Pack 5 have been installed on a system and BEFORE a system reboot.

In the event that the patch has not been applied and the system is unbootable (i.e. hanging during OS initialization) then to apply the patch you will need to do the following:

1) Reboot the server

2) Start the Server's BIOS configuration utility and disable Multi Processor support in the server BIOS.

Please refer to your server documentation for details of how to do this.

On a HP Server this can usually be done as follows:

Enter RBSU by pressing <F9> during boot Select "Advanced Options" Select "MPS Table Mode" Change MPS Table Mode value to "Disabled"

4) Save the BIOS settings and reboot the server

5) Apply OSS674a to the server and reboot

6) Start the Server's BIOS configuration utility and re-enable Multi Processor support.

Please note that this patch can be installed later if desired.

This supplement can be installed on the following SCO OpenServer releases:

SCO OpenServer Release 5.0.7 with Symmetrical Multiprocessing and Maintenance Pack 5

----------------------------------------------------------
I. Software Notes and Recommendations

1. If you have any questions concerning this supplement, please contact your SCO software supplier or your SCO Support Representative.

----------------------------------------------------------
II. Installation Instructions
To install OSS674A follow these steps:
1. Login as root

2. Create an empty directory, such as /tmp/oss674a, to which the patch will be downloaded.

3. Download the OSS674A patch file VOL.000.000 from
https://ftp.scoexpert.com/openserver5/507/patches/oss674a

to the directory created in step 2.

4. Run the Software Manager with the command:

scoadmin software

or double-click on the Software Manager icon in the desktop.

5. Pull down the "Software" menu and select "Install New".

6. When prompted for the host from which to install, choose the local machine and then "Continue".

7. In the "Select Media" menu, pull down the "Media Device" menu. Select "Media Images", then choose "Continue".

8. When prompted for the "Image Directory", enter "/tmp/oss674a" (or the directory where you placed the OSS674A patch file VOL.000.000 in step 2) and choose "OK."

9. When prompted to select software to install, make sure that
   the "OSS674A" entry is highlighted.  Choose "Install".

10. Installation of Escalation Supplement OSS674A is now complete. To exit the Software Manager, select "Exit" from the "Host" menu.

11. Once the installation has completed, you can remove or archive the downloaded patch, the media image files, and the containing directory created in step 2.

12. You will need to reboot your system for all changes to take effect.

----------------------------------------------------------
III. Removal Instructions

Note: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.

1. Log in as root.
2. Execute the command:
scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight the "OSS674A" entry.

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.

6. You will need to reboot your system for all changes to take effect.

NOTES:    If the installation complains the MP5 has not been loaded but it is
          visible on the 'custom' install list then it is likely that the SMP
          package was loaded 'post' MP5's installation.
To fix this within 'custom'
a) Remove OSS674 (Do not reboot)
b) Remove OSS672 (Do not reboot)

c) Remove MP5 (Do not reboot although you will be asked to leave the Software Manager, which is fine)

d) Run 'custom' again and install MP5, this should then detect the
   SMP additions.  Once installed, again, you will be asked to leave
   the Software Manager, which is fine and again do not reboot)
e) Install OSS672

At this point, you can reboot the server prior to attempting to load OSS674 again.

From the Xinuos technical article database, record 126891. Reproduced with permission. The original is at www.sco.com/ta/126891, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.