Technical article 125382

When using the PERC4/Di, PERC4/Si, PERC4/Dc, PERC4/Sc or the PCI PERC4 RAID management software (scomgr/unxwrmgr) the option to force a physical drive offline displays an error message.

OpenServer 5.0.6OpenServer 5.0.7UnixWare 7.1.3

Written · Last revised

Problem

When selecting the option to "Force Offline" in the scomgr and unxwrmgr utility's Physical Drive menu I see the following error messages:

On OpenServer (scomgr):

Cmd=0xF4 IssueCmd: Cmd not supported Press any key to continue

On UnixWare (unxwrmgr):

F4h - Opcode Not Supported Press any key to continue

HARDWARE: Dell PERC4/Di RAID controller
          Dell PERC4/Si RAID controller
          Dell PERC4/Dc RAID controller
          Dell PERC4/Sc RAID controller
          Dell PERC4 PCI RAID controller

Solution

This error message is harmless and may be safely ignored. After pressing a key the selected drive is forced offline and marked as FAILED.

Dell is aware of this issue and it will be addressed in a future perc driver release.

From the Xinuos technical article database, record 125382. Reproduced with permission. The original is at www.sco.com/ta/125382, which is reachable but blocked from search engines.