Problem

How to migrate Unixware7D2018 and OpenServer6D2018 VM's from VMware to Proxmox

Solution

To migrate Unixware7D2018 and OpenServer6D2018 VM's from VMware to Proxmox you follow the procedure mentioned in the proxmox doc wiki: https://pve.proxmox.com/wiki/Migrate_to_Proxmox_VE#Automatic_Import_of_Full_VM

Before starting the conversion the Unixware7D2018 and OpenServer6D2018 VM must be updated with the latest patches. For VMs connected to the internet this can be done using the patchck script. For offline VMs it can be done by running the install.sh script from the patchck iso that can be downloaded from https://download.xinuos.com/patchck Be sure also the vtblk driver is installed on the VM.

The conversion needs a special iso to boot from: For Unixware7D2018 download: https://download.xinuos.com/tools/emergency_cd/EmergencyCD_7Def_proxmox.iso For OpenServer6D2018 download: https://download.xinuos.com/tools/emergency_cd/EmergencyCD_6Def_proxmox.iso

Download the needed iso to your local proxmox ISO Images location. For most proxmox servers this is directory /var/lib/vz/template/iso.

To import the VM you can follow these steps: 1. Make sure that your Proxmox VE is on version 8 (or above) and has the latest available system updates applied. 2. Add an "ESXi" import-source storage, through the Datacenter -> Storage -> -> Add menu. Enter the domainname or IP-address and the credentials of an admin account here. Check the Skip Certificate Verification checkbox. Note: While one can also import through a vCenter instance, doing so will reduce performance. 3. Select the storage in the resource tree, which is located on the left. 4. Check the content of the import panel to verify that you can see all available VMs. 5. Select a VM you want to import and click on the Import button at the top. 6. Select at least the target storage for the VMs disks and network bridge that the VMs network device should connect to. 7. Use the Advanced tab if you want to import selected harddisks only. 8. Before you start the import, be sure the VMware VM down. 9. Start the actual import on the Proxmox side. 10. When the import is completed at 100%, then close the import task box

Note: The import may fail if the VMware VM has multiple snapshots.

If the import was completed correct, modify the imported VM: 1. Select the new imported VM -> Hardware 2. Double-click the "SCSI Controller" line and change the type to "Virtio SCSI single" 3. Select the first "Hard Disk", then press the 'Detach' button. The "Hard Disk" line is changed to "Unused Disk 0" now. Double-click the "Unused Disk 0" and change "Bus/Device" to "VirtIO Block". The name will be changed to "Hard Disk (virtio0)" now. Repeat these steps for all other harddisks. Make sure the disk numbers keep the same, scsi0 gets virtio0, scsi1 gets virtio1, etc. 4. Double-click the "Network Device (net0)" line and and change "Model" to "VirtIO (paravirtualized)". 5. Select the "CD/DVD Drive (ide0)" line, then press the 'Remove' button. Click the 'Add' => "CD/DVD" button and add a "Bus/Device" type "SATA" cd/dvd drive. Select an iso from your LOCAL storage: For OpenServer6D2018 select the EmergencyCD_6Def_proxmox.iso For Unixware7D2018 select the EmergencyCD_7Def_proxmox.iso

6. Navigate to the 'Options' configuration selection: Double-click the "BootOrder" line and enable sata0 and virtio0. Drag and Drop the items to set the sata0 as first bootdevice, virtio0 as second. 7. Also in the 'Options' menu, change "Use local time for RTC" to 'Yes'.

8. Navigate to the "Console" and start the VM. It should boot from CD/DVD now. After a few seconds a blue screen will appear telling the drivers will be loaded. If the diskcontroller and disks were set to virtio, then after some moments the screen will display "The disk is sane". 9. After pressing 'Enter' a menu will be displayed. Select menu option "Mount File Systems" to mount / and /stand to /mnt. Select menu option "Access server Shell" to enter a command screen. 10.Execute the "convert2proxmox" command. It will change the bootdisk settings, deactivate the VMWare tools and install a temporary kvm platform license on the VM. At the end it will umount the / and /stand, you can enter 'exit' and reboot the VM. The screen will ask to remove the CD before reboot. Double-click on "CD/DVD Drive (sata0)" and select "Do not use any media". Then reboot the VM from the console menu. 11.After booting fom harddisk in single- or multi-user mode, you need to execute netcfg utility to add the VirtIO card. The VirtIO NIC is automatically selected when a new card is added. Reboot the VM after the new card is configured

The conversion of the VM to Proxmox is now completed. Be aware there is a 30day temporary kvm platform license on the VM. A permanent license should be installed as soon as possible.

Please check the /etc/vfstab file after conversion. Filesystems on addditional disks may not be mounted correct after reboot.

Note: Openserver5 VM's are not supported on Proxmox Note: VM Live migration is not supported.

From the Xinuos technical article database, record 128148. Reproduced with permission. The original is at www.sco.com/ta/128148, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.