Problem
I have a server with multiple SCSI controllers in it. When I install SCO OpenServer 6.0.0, the ISL installation picks up the wrong SCSI controller as the boot controller.
Is there a way, similar to UnixWare 7 ISL DCU, to influence the boot controller order during the installation? In other words, is there a DCU in SCO OpenServer 6.0.0 Installation?
Solution
Yes, there is a DCU during the installation of SCO OpenServer 6.0.0.
To get to the OSR6 ISL DCU, continue the installation until you reach the ISL screen with:
Available Drivers - All Drivers SelectedIn the bottom of the screen you will see that there is a F8 key for DCU "F8=DCU".
Press F8 and then choose "Interactively configure drivers".
This will then run DCU and you can then manipulate the SCSI controller order.
Save the changes in the DCU and you will be taken back to the OpenServer 6 installation screen to continue.
NOTES: The other way to prevent SCO OpenServer 6.0.0 to be
installed on the wrong SCSI controller, is to disable
all NON boot SCSI controller BIOS and leave only the
boot SCSI controller BIOS enabled.