Technical article 126628

How can I get a DELL PowerVault 220S / 221S Storage Subsystem to work in an HA shared storage environment under SCO Operating Systems?

OpenServer 6.0.0UnixWare 7.1.3UnixWare 7.1.4

Written · Last revised

Problem

how can I get a DELL PowerVault 220S / 221S Cluster Storage Subsystem to work in an HA shared storage environment under SCO OpenServer 6.0.0 and SCO UnixWare 7.1.3 / 7.1.4?

HARDWARE: DELL PowerVault 220S / 221S Cluster SCSI Storage Subsystem. DELL PERC 4/DC (PCI Dual Channel). DELL PERC 4e/DC (PCI Express Dual channel). 2x DELL PowerEdge 1800 SCSI (Tower) 2x DELL PowerEdge 2650 (Rack) 2x DELL PowerEdge 2850 (Rack)

NOTE: DELL PERC 4/Dc is the OEM version of LSI MegaRAID 320-2 DELL PERC 4e/Dc is the OEM version of LSI MegaRAID 320-2E

Solution

Make sure you follow the below points step-by-step:

1 Make sure that both Nodes (servers) are disconnected from the DELL PowerVault Storage Subsystem

2 check that the following BIOS and firmware are up-to-date.

Note: the latest BIOS and firmware for the DELL PERC 4/DC and 4e/DC are available on DELL Website

http://support.dell.com/support/downloads/type.aspx?c=us&l=en&s=gen&SystemID=PWE_PNT_P3C_2850&os=LE30&osl=en&deviceid=6395&libid=35

Both PERC 4/DC and 4e/DC latest BIOS/Firmware release is 521X.

If your DELL PERC 4/DC or 4e/DC is not up-to-date with the above BIOS and firmware releases, then perform the BIOS and Firmware upgrade on them.

3 While the SCSI cable is disconnected between the two servers DELL PERC Raid) and the PowerVault 220S / 221S cluster, boot both servers and enter the PERC 4/DC or 4e/DC browser based BIOS configuration utility (WebBIOS) by keying <Ctrl><H>.

make sure you have the following BIOS settings.
4 On Node (Server) one:
Under "Adapter Properties" link,
Cluster Mode *        = Enabled      (Default is Disabled)
Initiator ID          = 7            (Default is 7)
Adapter BIOS *, **    = Disabled     (Default Enabled)
Fast Initialization * = Enabled      (Default is Disabled)
Class Emulation Mode  = Mass Storage (Default is Mass Storage)

* Need changing from the default setting. ** Adapter BIOS is disabled, as it will not be used for OS booting.

Save the setting and power off the server.

On Node (Server) two:
Under "Adapter Properties" link,
Cluster Mode *        = Enabled      (Default is Disabled)
Initiator ID *        = 6            (Default is 7)
Adapter BIOS *, **    = Disabled     (Default Enabled)
Fast Initialization * = Enabled      (Default is Disabled)
Class Emulation Mode  = Mass Storage (Default is Mass Storage)

* Need changing from the default setting. ** Adapter BIOS is disabled, as it will not be used for OS booting.

VERY IMPORTANT, that the Initiator ID on the second PERC RAID controller should be set to ID=6. If left at 7, then the cluster functionality within the controller will fail due to conflict with the Initiator ID on the first PERC RAID controller.

Save the setting and power off the server.

5 Make sure on the DELL PowerVault, the Bus Configuration Switch is
  set to "Cluster", the lower possition. This switch you can find
  on the back of the PowerVault 220s / 221S.

6 Connect (Cable) the first Node PERC RAID ONLY to the PowerVault 220S / 221S Storage subsystem. Leave the second one not connected at this stage.

Power on Node one and enter the PERC RAID configuration utility "WebBIOS" with <Ctrl><H> and check that the controller sees all the physical disks on the PowerVault 220S / 221S. Setup the Logical RAID drives (Array disks).

Save the settings and initialize the newly created logical raid drives. The initialization will be very fast. Do not reboot the server at this stage yet.

7 Connect (Cable) the second Node PERC RAID to the PowerVault Storage Subsystem.

Power on Node two and enter the PERC RAID configuration utility "WebBIOS" with <Ctrl><H> and check that the controller sees all the configured logical RAID drives on the PowerVault 220S / 221S, that where created by Node one.

If so, then now both nodes PERC RAID are correctly cabled and set up to work with the PowerVault 220s / 221S Storage Subsystem in a Cluster (shared Storage) environment.

8 You can now install SCO OpenServer 6.0.0 or UnixWare 7.1.3 / 7.1.4 on the first node and then create in the post installation the Unix filesystems (via UW7 "diskadd" or OSr6 "mkdev hd") on the Logical RAID Drives in the PowerVault 220s / 221S Storage Subsystem.

9 Install SCO OpenServer 6.0.0 or UnixWare 7.1.3 / 7.1.4 on the second node.

SCO UnixWare 7.1.3 / 7.1.4 will auto detect the generated filesystems on the PowerVault 220s / 221S and will create the associated devices for the filesystems.

for OpenServer 6.0.0, you need to run "mkdev hd" and choose the created logical RAID drives on the PowerVault 220s / 221S and within "divvy" configuration ONLY update the filesystem names (To be the same as in the first node).

WARNING: "FS" field should be set to "No"

With this, the associated devices for the filesystems will be created.

Both systems are now ready to be used for shared storage HA environment.

NOTES:    The above is not an SCO official certified solution, but has been
          setup and reported by SCO field engineers to work in HA environment.

See also

TA126627:"How can I get a Fujitsu Siemens Computers PRIMERGY SX30 Cluster Storage Subsystem to work in a HA shared storage environment under SCO OpenServer 6.0.0 and SCO UnixWare 7.1.3 / 7.1.4?

From the Xinuos technical article database, record 126628. Reproduced with permission. The original is at www.sco.com/ta/126628, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.