Technical article 127241

I see getty errors while booting OpenServer 6 with my Equinox SST multiport serial adapter.

OpenServer 6.0.0

Written · Last revised

Problem

I see getty errors while booting OpenServer 6 with my Equinox SST multiport serial adapter, however, my users are still able to login on the enabled SST ports.

*** /etc/getty -t60 tty1a1 m (Wed Dec 31 16:20:07 2008), PID 2407: Cannot open line tty1a1: No such file or directory (error 2)

HARDWARE: Equinox SST Multiport Serial Adapter

Cause

The getty commands that enable the ports are running before the Equinox dynamic driver modules have completely initialized the ports.

Solution

To workaround this problem, you can make the Equinox drivers static so that they become part of the boot kernel and therefore initialize the ports sooner.

To do this take these steps:

1) Edit each of the Equinox driver files:

# cd /etc/conf/sdevice.d
# vi eqn eqnlp eqnt

For each file add a line below the $version line with:

$static
2) Update the Equinox initialization script:
# cd /etc/idrc.d
# vi eqn

Comment out the modadmin -l lines like this:

##/sbin/modadmin -l eqn
##/sbin/modadmin -l eqnlp
##/sbin/modadmin -l eqnt

3) relink the kernel and reboot the system:

# cd /etc/conf/cf.d
# ./link_unix
# shutdown -g0 -i6

Now you should no longer see the Equinox getty errors.

From the Xinuos technical article database, record 127241. Reproduced with permission. The original is at www.sco.com/ta/127241, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.