Technical article 127502

Is there a Tape Media Compatibility Matrix for HP tapes?

OpenServer 6.0.0

Written · Last revised

Problem

Is there a Tape Media Compatibility Matrix for tapes?

Solution

For DDS/DAT visit:
http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?objectID=lpg50457&locale=en_US&taskId=101&prodSeriesId=81997&prodTypeId=12169
Which details:
Overview:

The DDS (Digital Data Storage) formats build on the 4 mm DAT (Digital Audio Tape) format to meet the more stringent needs of computer data storage. As the DDS technology has developed, so new standards have been produced, each allowing more data to be stored on a single cartridge. Briefly, the development of the DDS formats to date has been as follows:

DDS-1 - DDS-1 was originally called DDS. It used 60m and 90m cartridges and did not allow hardware data compression.

DDS1-DC DDS1-DC, or simply DDS-DC - extended DDS-1 to include hardware data compression. This typically doubled the capacity of a tape.

DDS-2 - DDS-2 included the features of DDS-1 and DDS-DC, but increased the amount of data that could be written to a single cartridge in two ways: It used longer, thinner tapes (120m). It wrote data in narrower tracks. Together these features meant that a DDS-2 tape could hold twice the data of a DDS-1 90m tape.

DDS-3 - DDS-3 stores data at twice the density of DDS-1 and DDS-2, and also allows more of the tape to be used for data. As a result, a DDS-3 (125m) tape holds three times the data of a DDS-2 tape.

DDS-4 - DDS-4 tape, at 150m, is longer than DDS-3 (125m) tape. It holds holds two-thirds more data than a DDS-3 tape.

DAT-72 - DAT-72 tapes are 170m long and data is written in narrower tracks, again increasing data density, enabling tapes to hold 80% more data than DDS-4 tapes.

DAT-160 - DAT-160 tapes are 154m long and data is written at a higher density than DAT-72, enabling the tapes to store up to 160GB of data.

Choosing Cartridges: To exploit the full potential of a DDS-format drive, matching cartridges should be used: DDS-3 cartridges for DDS-3 drives, DDS-4 cartridges for DDS-4 drives, and DAT 72 cartridges for DAT 72 drives.

This will allow the drives to store the maximum amount of data on a tape.

However, HP DDS drives are backward compatible. This means that, for example, a DAT 72 drive can read and write DDS-4 tapes. Note that it will use DDS-4 format, so the full advantage of DAT 72 will be lost. Drives are not forward compatible, so, for example, a DDS-4 drive cannot read or write a DAT 72 tape. It will simply eject it

DDS-1 StorageWorks Media
(60m/90m)  DDS-2 StorageWorks Media
(DAT-8)  DDS-3 StorageWorks Media
(DAT-24)  DDS-4 StorageWorks Media
(DAT-40)  DAT-72 StorageWorks Media  DAT-160 StorageWorks Media
DDS1  DDS2    DDS3  DDS4  DAT-72 DAT-160
HP Surestore 2000/5000       W/R   No      No    No    No     No
HP Surestore/StorageWorks
DAT 8                        W/R   W/R     No    No    No     No
HP Surestore/StorageWorks
DAT 24/24x6                  W/R   W/R     W/R   No    No     No
HP StorageWorks DAT40
Hotplug                      No    R Only  W/R   W/R   No     No
HP Surestore/StorageWorks
DAT 40/40x6                  No    W/R     W/R   W/R   No     No
HP StorageWorks DAT 24 USB   No    W/R     W/R   No    No     No
HP StorageWorks DAT 40 USB   No    W/R     W/R   W/R   No     No
HP StorageWorks DAT 72 USB   No    No      W/R   W/R   W/R    No
HP StorageWorks DAT-72
/ 72x6                       No    No      W/R   W/R   W/R    No
HP StorageWorks DAT-160 SCSI
Tape Drive                   No    No      No    W/R   W/R    W/R
HP StorageWorks DAT-160
USB Tape Drive               No    No      No    W/R   W/R    W/R
Where W/R means Write/Read.
For LTO visit:
http://www.imation.com/PageFiles/271/Ultrium_Compatibility.pdf
LTO Cart        Gen 1 Drive    Gen 2 Drive   Gen 3 Drive   Gen 4 Drive
Gen 1           W/R @100GB     W/R @100GB    Read Only     Not Function
Gen 2           Not Function   W/R @200GB    W/R @200GB    Read Only
Gen 3           Not Function   Not Function  W/R @400GB    W/R @400GB
Gen 4           Not Function   Not Function  Not Function  W/R @800GB

Information was correct at time of writing.

From the Xinuos technical article database, record 127502. Reproduced with permission. The original is at www.sco.com/ta/127502, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.