Technical article 113164

My application returns SOCKET accept failed [errno 126] when I try to open over 200 sockets every second.

OpenServer 6.0.0UnixWare 7.1.1UnixWare 7.1.3UnixWare 7.1.4

Written · Last revised

Problem

My application returns SOCKET accept failed [errno 126] when I try to open over 200 sockets every second.

Cause

From /usr/include/sys/errno.h we can see that error 126 refers to:

#define EADDRNOTAVAIL   126             /* Can't assign requested address */

This is not defined in "man 3 accept" but is in "man tcp": [EADDRNOTAVAIL]

When an attempt is made to create a socket with a network address for which no network interface exists

Solution

There are a number of steps we can take to try to alleviate the problem:

1. Visit https://ftp.scoexpert.com/unixware7/drivers/network/ for a list of the latest network drivers available for your Network Interface Card (NIC).

2. Visit https://ftp.scoexpert.com/unixware7 for a list of the latest patches for UnixWare7.

3. You may wish to turn off network services not being used by the
   server from /etc/rc2.d.  For example, SENDMAIL.
   More information on this can be found from TA 111865,
   "How do I tune my UnixWare 7 server to run Tarantella?"
4. TCP/IP Tuning

The following values can be increased to improve TCP/IP performance:

ulimit:
# ulimit unlimited
(tcp_2msl)
The tcp_2msl parameter defines the time connections will remain
in TIME_WAIT state - see RFC793.  By default the value is 240
(4minutes).  It can be reduced to 30 seconds with the following:
inconfig tcp_2msl 30
(tcp)

"tcp" is the maximum number of simultaneous tcp connections on a server.

The configuration file is in /etc/conf/sdevice.d (3rd field)

The factory default is 1000 and the maximum can be set to 4096.

The limitation is related to select() /FD_SETSIZE which limits the number of File Descriptors (FD) opened to 4096.

"man 3 select" states:

The behavior of these macros is undefined if a descriptor value is less than zero or greater than or equal to FD_SETSIZE. FD_SETSIZE is a constant defined in sys/select.h.

In UnixWare 7 and previous releases of UnixWare, its value
was 1024. FD_SETSIZE was increased to 4096 in UnixWare 7
Release 7.0.1. See ``Notices''.
(ticots)

/dev/ticots is typically invoked as the implied device in a call to socket or as the first argument in a call to t_open and is used to identify the transport protocol that will supply a connection-based transport service.

Basically, ticots is the module which is opened when you open a connection-oriented Unix domain socket.

The configuration file is in /etc/conf/sdevice.d (3rd field)

The factory default is 256 and the maximum can be set to 8192.

(ticlts)

This appears to be the connectionless Unix domain socket (AF_UNIX,SOCK_DGRAM)

The configuration file is in /etc/conf/sdevice.d (3rd field)

The factory default is 256 and the maximum can be set to 1000.

(ticotsor)

This is the connection-oriented unix domain sockets (UDS) with "orderly release".

The configuration file is in /etc/conf/sdevice.d (3rd field)

The factory default is 256 and the maximum can be set to 1000.

"ticots", and "ticotsor" are connection-oriented loopback transport provider that is used for unix domain sockets within a system, rather than over a network. "ticlts" is actually connectionless.

There is another tuneable ipport_reserved_high which increases the number of allowed privileged ports. You can try increasing it to 2048.

NOTE:     The factory default values may change per release.

See also

ta111586, "Understanding, debugging and tuning UnixWare 7
          telnet connections."

ta111865, "How do I tune my UnixWare 7 server to run Tarantella?" select(3C)

From the Xinuos technical article database, record 113164. Reproduced with permission. The original is at www.sco.com/ta/113164, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.