Technical article 126691

My HP Proliant ML370-G5 sporadically reboots with HP EFS 5.74a for SCO OpenServer 5.0.7 or EFS 7.74a for SCO UnixWare 7.1.4 installed and the ASR in the BIOS enabled.

OpenServer 6.0.0OpenServer 5.0.7UnixWare 7.1.4

Written · Last revised

Problem

I have installed SCO OpenServer 5.0.7 successfully on HP
Proliant  ML370-G5 and also installed the whole HP EFS 5.74a.
But my server sporadically reboots without any warnings or
explanations.

I have disabled the ASR (advanced Server Recovery) in the BIOS and this has stopped the sporadic reboot, but I get this error message on the console when the OS is booted:

WARNING: hpasmxl: Failed GET SENSOR READING (0x000000C7) sensor 20 WARNING: hpasmxl: Failed GET SENSOR READING (0x000000C7) sensor 16 WARNING: hpasmxl: NetFN 0x00000036, command 0x00000002 timed out WARNING: hpasmxl: NetFN 0x00000036, command 0x00000002 timed out WARNING: hpasmxl: NetFN 0x00000036, command 0x00000002 timed out

I see the same issue when installing SCO Unixware 7.1.4 or Openserver 6.0.0 and HP EFS 7.74a.

how can the sporadic reboot be prevented?

Cause

There is a bug in the underline "hpasmxl" driver that is present in the HP EFs 5.74a or HP 7.74a. This due to KCS request packet corruption, thus causing the sporadic reboot.

Solution

HP has updated their EFS with the latest that fixes this issue. (EFS = Extended Feature Supplement)

For SCO OpenServer 5.0.7, the EFS is addresses this issue is EFS 5.790a and is available from SCO Support or from HP at:

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=0&prodSeriesId=1121516&prodNameId=1157693&swEnvOID=1068&swLang=8&mode=2&taskId=135&swItem=MTX-8a01f00748d5406cb5f41e9298
On the release note:

Fixes: Resolved ASR reboot issue, seen due to KCS Request Packet corruption.

For SCO OpenServer 6.0.0 & Unixware 7.1.4, the latest EFS to address this issue is the PSP (Proliant Support Pack), from PSP 7.70a and the latest version, v7.811a is available from SCO Support or from HP at:

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=15351&prodSeriesId=1121474&prodNameId=3279719&swEnvOID=2010&swLang=8&mode=2&taskId=135&swItem=MTX-0fa3805e9ad44b02b34bb0e818

If you do not want to upgrade to HP EFS 7.770a or PSP 7.70a and want to stay with previous release of HP EFS 5.74a or 7.74a and want to avoid the sporadic reboot, then you need to disable the ASR in the system BIOS and when installing the HP EFS 5.74a or EFS 7.74a and make sure that you DO NOT install the Embedded Health Driver (hpasm - Earlier models then G5) or (hpasmxl - Model G5 and above).

The latest verision of this package, 7.811a, is available from:

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?lang=en&cc=us&prodTypeId=15351&prodSeriesId=1121474&prodNameId=3279719&swEnvOID=2010&swLang=8&mode=2&taskId=135&swItem=MTX-0fa3805e9ad44b02b34bb0e818

See also

http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&objectID=c01498711

From the Xinuos technical article database, record 126691. Reproduced with permission. The original is at www.sco.com/ta/126691, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry