Technical article 127612

What is Security Supplement p535239b, the sco_pmd security fix for OpenServer 6.0.0?

OpenServer 6.0.0

Written · Last revised

Problem

What is Security Supplement p535239b, the sco_pmd security fix for OpenServer 6.0.0?

Solution

The supplement fixes a potential DOS vulnerability of sco_pmd.

What follows is the Security Advisory for this fix:

______________________________________________________________________________
SCO Security Advisory
Subject:                sco_pmd security fix for OpenServer 6.0.0
Advisory number:        SCOSA-2011.2
Issue date:             20th July 2011
Cross reference:        fz535239
______________________________________________________________________________
1. Problem Description

Security Supplement p535239b, the sco_pmd security fix for OpenServer 6.0.0, addresses a potential denial of service vulnerability of sco_pmd.

2. Vulnerable Supported Versions
System                          Package
----------------------------------------------------------------------
OpenServer 6.0.0                Maintenance Pack 4
3. Solution

The proper solution is to install the relevant package below.

4. OpenServer 6.0.0

This patch should only be installed on OpenServer 6.0.0 systems with Maintenance Pack 4 installed.

4.1 Location of Fixed Binaries
https://ftp.scoexpert.com/openserver6/600/security/p535239b_osr6/
4.2 Verification
# sum -r p535239b_vol.tar
12225   107 p535239b_vol.tar
MD5 (p535239b_vol.tar) = cae430782b7d499ce1dea1e31bbec460
md5 is available for download from
https://ftp.scoexpert.com/security/tools
# /usr/bin/shasum p535239b_vol.tar
9f535672663e78682a6b1494eda2bae897d295e8  p535239b_vol.tar

/usr/bin/shasum is part of the perl-5.8.8 extension package included in Maintenance Pack <X>.

Alternatively /usr/gnu/bin/sha1sum included in the GNU Utilities can be used:

# /usr/gnu/bin/sha1sum p535239b_vol.tar
9f535672663e78682a6b1494eda2bae897d295e8  p535239b_vol.tar
4.3 Installation Instructions
To install P535239B follow these steps:
1. Login as root

2. Create an empty directory, such as /tmp/p535239b, to which the patch will be downloaded.

3. Download the P535239B patch file p535239b_vol.tar to the directory created in step 2.

4. After the download is complete, change to the directory containing the p535239b_vol.tar file and run the following to extract the media image files:

tar xvf p535239b_vol.tar

5. Run the Software Manager with the command:

scoadmin software

or double-click on the Software Manager icon in the desktop.

6. Pull down the "Software" menu and select "Install New".

7. When prompted for the host from which to install, choose the local machine and then "Continue".

8. In the "Select Media" menu, pull down the "Media Device" menu. Select "Media Images", then choose "Continue".

9. When prompted for the "Image Directory", enter "/tmp/p535239b" (or the directory where you placed the P535239B patch file p535239b_vol.tar in step 2) and choose "OK."

10. When prompted to select software to install, make sure that
    the "P535239B" entry is highlighted.  Choose "Install".
    Once installation is complete, select "OK".

11. Installation of Escalation Supplement P535239B is now complete. To exit the Software Manager, select "Exit" from the "Host" menu.

12. Once the installation has completed, you can remove or
    archive the P535239B patch file p535239b_vol.tar, the
    media image files, and the containing directory created
    in step 2.

13. Reboot the system after installing this supplement.

4.4 Removal Instructions

Note: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.

1. Log in as root.
2. Execute the command:
scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight the "P535239B" entry.

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.

6. It is necessary to reboot your system after removal.

5. References
SCO security resources:
        http://www.sco.com/support/download.html
SCO security advisories via email
        http://www.sco.com/support/forums/security.html

This security fix closes SCO incidents fz535239.

6. Disclaimers

SCO is not responsible for the misuse of any of the information we provide on this website and/or through our security advisories. Our advisories are a service to our customers intended to promote secure installation and use of SCO products.

7. Acknowledgments
N/A

From the Xinuos technical article database, record 127612. Reproduced with permission. The original is at www.sco.com/ta/127612, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.