Technical article 126912

What is Support Level Supplement (SLS) OSS707A, the OpenServer 6 Platform Support Update?

OpenServer 6.0.0

Written · Last revised

Problem

What problems are fixed by Support Level Supplement (SLS) OSS707A, the OpenServer 6 Platform Support Update?

Solution

OSS707A fixes the following two problems related to multicore and hyperthread support:

1.  The LAPIC_SORT=Y boot directive was ignored, which in
    some cases could result in not all processors being
    detected by the OS.
2.  Systems on which the processor supports hyperthreading but
    on the BIOS has hyperthreading disabled may have the
    number of available processors reduced by a factor of 2.

This supplement can be installed on the following SCO OpenServer releases:

SCO OpenServer Release 6.0.0 with Maintenance Pack 2 and OSS706C, the OpenServer 6 Maintenance Pack 2 Supplement

----------------------------------------------------------
I. Software Notes and Recommendations

1. If you have any questions concerning this supplement, please contact your SCO software supplier or your SCO Support Representative.

----------------------------------------------------------
II. Installation Instructions
To install OSS707A follow these steps:
1. Login as root

2. Create an empty directory, such as /tmp/oss707a, to which the patch will be downloaded.

3. Download the OSS707A patch file VOL.000.000 from
https://ftp.scoexpert.com/openserver6/600/patches/oss707a

to the directory created in step 2.

4. Run the Software Manager with the command:

scoadmin software

or double-click on the Software Manager icon in the desktop.

5. Pull down the "Software" menu and select "Install New".

6. When prompted for the host from which to install, choose the local machine and then "Continue".

7. In the "Select Media" menu, pull down the "Media Device" menu. Select "Media Images", then choose "Continue".

8. When prompted for the "Image Directory", enter "/tmp/oss707a" (or the directory where you placed the OSS707A patch file VOL.000.000 in step 2) and choose "OK."

9. When prompted to select software to install, make sure that
   the "OSS707A" entry is highlighted.  Choose "Install".

10. Once installation of SLS OSS707A has completed, exit the Software Manager by selecting "Exit" from the "Host" menu.

11. If desired, remove or archive the downloaded patch file and remove the containing directory created in step 2.

12. You will need to reboot your system for all changes to take effect.

----------------------------------------------------------
III. Removal Instructions

Note: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.

1. Log in as root.
2. Execute the command:
scoadmin software

or double-click on the Software Manager icon in the desktop.

3. Highlight the "OSS707A" entry.

4. Pull down the "Software" menu and select "Remove Software".

5. Once the removal finishes, quit the Software Manager.

6. You will need to reboot your system for all changes to take effect.

From the Xinuos technical article database, record 126912. Reproduced with permission. The original is at www.sco.com/ta/126912, which is reachable but blocked from search engines.

Next step

Need this fixed rather than explained?

Tell us the release, what the system runs and what it is doing. We will reply by email with what we would do next.

  • You deal with the people who do the work
  • No obligation, and no upgrade required before we will help
  • We tell you plainly if something is not worth doing

Send an enquiry

We reply by email. If a server is down, say so in the first line. You can also write to help@scoexpert.com.