Problem
What problems are fixed by Support Level Supplement (SLS) OSS707B, the OpenServer 6 Platform Support Update?
Solution
OSS707B fixes the following two problems related to multicore and hyperthread support:
1. The LAPIC_SORT=Y boot directive was ignored, which in
some cases could result in not all processors being
detected by the OS.2. Systems on which the processor supports hyperthreading but
on which the BIOS has hyperthreading disabled may have the
number of available processors reduced by a factor of 2.This supplement can be installed on the following SCO OpenServer releases:
SCO OpenServer Release 6.0.0 with Maintenance Pack 3----------------------------------------------------------I. Software Notes and Recommendations1. If you have any questions concerning this supplement, please contact your SCO software supplier or your SCO Support Representative.
----------------------------------------------------------II. Installation InstructionsTo install OSS707B follow these steps:1. Login as root2. Create an empty directory, such as /tmp/oss707b, to which the patch will be downloaded.
3. Download the OSS707B patch file VOL.000.000 fromhttps://ftp.scoexpert.com/openserver6/600/patches/oss707bto the directory created in step 2.
4. Run the Software Manager with the command:
scoadmin softwareor double-click on the Software Manager icon in the desktop.
5. Pull down the "Software" menu and select "Install New".
6. When prompted for the host from which to install, choose the local machine and then "Continue".
7. In the "Select Media" menu, pull down the "Media Device" menu. Select "Media Images", then choose "Continue".
8. When prompted for the "Image Directory", enter "/tmp/oss707b" (or the directory where you placed the OSS707B patch file VOL.000.000 in step 2) and choose "OK."
9. When prompted to select software to install, make sure that
the "OSS707B" entry is highlighted. Choose "Install".10. Once installation of SLS OSS707B has completed, exit the Software Manager by selecting "Exit" from the "Host" menu.
11. If desired, remove or archive the downloaded patch file and remove the containing directory created in step 2.
12. You will need to reboot your system for all changes to take effect.
----------------------------------------------------------III. Removal InstructionsNote: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.
1. Log in as root.2. Execute the command:scoadmin softwareor double-click on the Software Manager icon in the desktop.
3. Highlight the "OSS707B" entry.4. Pull down the "Software" menu and select "Remove Software".
5. Once the removal finishes, quit the Software Manager.
6. You will need to reboot your system for all changes to take effect.