Problem
What problem is fixed by Escalations Supplement OSS710A, the OpenServer 6.0.0 Xenix Compatibility Update?
Solution
OSS701A, the OpenServer 6.0.0 Xenix Compatibility update fixes the following problems:
Some locking calls from Xenix applications failed because
the Xenix emulator failed to set the return value to 0
in some cases. The problem has been fixed.Some fcntl and locking calls from Xenix applications failed because
both the Xenix emulator and the kernel converted Xenix-domain
values into the native SVR5-ABI domain. This sometimes resulted
in double conversions, in turn causing erroneous values to be used
in some file locking system calls. This problem caused several
applications, including FoxBase+, that worked prior to the
installation of Maintenance Pack 3 (MP3) to fail. The problem
has been fixed by performing these translations only in the
Xenix emulator.An error in the management of the open file table maintained by
the Xenix emulator on behalf of Xenix applications caused some
Xenix applications to fail. This problem affected file descriptors
that had been duped or had been created by duping another file
descriptor. This problem has been fixed.This supplement can be installed on the following SCO OpenServer releases:
SCO OpenServer Release 6.0.0 with Maintenance Pack 3----------------------------------------------------------I. Software Notes and Recommendations1. If you have any questions concerning this supplement, please contact your SCO software supplier or your SCO Support Representative.
----------------------------------------------------------II. Installation InstructionsTo install OSS710A follow these steps:1. Login as root2. Create an empty directory, such as /tmp/oss710a, to which the patch will be downloaded.
3. Download the OSS710A patch file VOL.000.000 from:
https://ftp.scoexpert.com/openserver6/600/patches/oss710ato the directory created in step 2.
4. Run the Software Manager with the command:
scoadmin softwareor double-click on the Software Manager icon in the desktop.
5. Pull down the "Software" menu and select "Install New".
6. When prompted for the host from which to install, choose the local machine and then "Continue".
7. In the "Select Media" menu, pull down the "Media Device" menu. Select "Media Images", then choose "Continue".
8. When prompted for the "Image Directory", enter "/tmp/oss710a" (or the directory where you placed the OSS710A patch file VOL.000.000 in step 2) and choose "OK."
9. When prompted to select software to install, make sure that
the "OSS710A" entry is highlighted. Choose "Install".10. Installation of Escalation Supplement OSS710A is now complete. To exit the Software Manager, select "Exit" from the "Host" menu.
11. Once the installation has completed, you can remove or
archive the OSS710A patch file VOL.000.000 and the containing
directory created in step 2.12. You will need to reboot your system for all changes to take effect.
----------------------------------------------------------III. Removal InstructionsNote: Patches must be rolled back in the reverse order in which they were installed on a per-component basis.
1. Log in as root.2. Execute the command:scoadmin softwareor double-click on the Software Manager icon in the desktop.
3. Highlight the "OSS710A" entry.4. Pull down the "Software" menu and select "Remove Software".
5. Once the removal finishes, quit the Software Manager.
6. You will need to reboot your system for all changes to take effect.